Type | Description |
---|---|
Probe Type | K |
Display Type | Dot Matrix |
Features | Alarm, Backlight, Laser Sight, Memory, Min/Max/Dif/Ave |
Temperature Display | C°/F° |
Includes | Case, Software, Thermocouple - K-Type Bead Probe |
Battery Cell Size | AA (2) |
Input Type | Infrared; Thermocouple |
Standard Package | 1 |
Temperature Range | -40 ~ 1202°F (-40 ~ 650°C) |
Type | Handheld, Gun |
Absolute Maximum Temperature Measurement | +650°C |
Best Accuracy | ±1 % |
Calibrated | RSCAL |
Data Storage | Yes |
Dimensions | 254 x 191 x 69mm |
Distance to Spot Ratio | 30:1 |
Emissivity | 0.1 → 1 |
Height | 69mm |
Length | 254mm |
Model Number p | Fluke 566 |
Resolution | 0.1 °C |
Response Time | 500 ms |
Temperature Scale | Centigrade, Fahrenheit |
Weight | 965g |
Width | 191mm |
rohs | Not Applicable |
Factory Pack Quantity | 1 |
Product Category | Environmental Test Equipment |
Display Count | 3 |
Measures | Temperature |
Equipment Type | Thermometer |
Part # Aliases | 2837799 |
Accuracy | 1 % |
RoHS | RoHS Compliant By Exemption |
Temperature Measuring Range | :-40°C to +650°C |
Accuracy % | :1% |
Wavelength Max | :670nm |
Operating Temperature Min | :0°C |
Operating Temperature Max | :50°C |
SVHC | :No SVHC (20-Jun-2013) |
Battery Lifetime | :12h |
Battery Size Code | :2 x AA |
Laser Class | :Class 2 |
Operating Temperature Range | :0°C to +50°C |
Weight (kg) | 0.97 |
Tariff No. | 90251920 |
BatteryType | 2AA |
DistancetoSpotSizeRatio | 30:1 |
MeasurementUnits | °C,°F |
PrimaryType | Infrared/Contact |
SpectralResponse | 8-14μ |
TemperatureRange | –40to650°C |
ThermocoupleType | K |
Time,Response | <500mSec |
Non-contact temperature measuring resolution | 0,1°C |
Meter type | infra-red thermometer |
Body dimensions | 254 x 191 x 69mm |
Temperature measuring accuracy (measurement with probe) | ±1% or ±1°C |
Optical resolution | 30:1 |
Multiplicity | 1 |
Power supply | 2 batteries 1,5V LR6 (AA) |
Temperature measuring range for contact temperature measurement | -270...1372°C |
Emissivity value | 0,1...1 |
Gross weight | 1.04 kg |
Non-contact temperature measuring range | -40...650°C |
Emissivity resolution | 0.01 |
Response time | |
Weight with battery | 965g |
Display | LCD (98x96 pixels) |
Non-contact temperature measuring accuracy | ±1% or ±1°C |
RESOURCE TYPE | LINK |
---|---|
Datasheets | 566_568 User Manual |
Datasheets | 566,568 |