Image shown is a representation only. Exact specifications should be obtained from the product datasheet.
| Type | Description |
|---|---|
| Mounting | DIN Rail |
| Standard Package | Bulk |
| Series | * |
| Other Names | WAS5 VVC HF V/V SC |
| rohs | Lead free / RoHS Compliant |
| Insulation voltage input or output/supply | 1.2 kVeff / 5 s |
| Power consumption | < 1.3 W @ IOUT = 5 mA |
| ETIM 3*0 | EC001774 |
| Pollution severity | 2 |
| Impulse withstand voltage | 4 kV |
| Engineering data | EPLAN |
| Net weight | 100.2 g |
| eClass 9*1 | 27-21-01-20 |
| Tightening torque, max | 0.5 Nm |
| eClass 7*1 | 27-21-01-20 |
| Width | 17.5 mm |
| Version | Signal converter/insulator, Screw connection |
| Cut-off frequency (-3 dB) | ≥ 15 kHz (typ. 20 kHz) |
| Stripping length, rated connection | 7 mm |
| Width (inches) | 0.689 inch |
| GTIN (EAN) | 4032248100668 |
| load impedance voltage | ≥ 2 kΩ |
| Type | WAS5 VVC HF 0-10/0-10V |
| Declaration of Conformity | Declaration of Conformity |
| Accuracy | ± 0.2 % of final value |
| Number of outputs | 1 |
| Length (inches) | 3.638 inch |
| Tightening torque, min | 0.4 Nm |
| Output voltage, note | 0...10 V |
| Insulation voltage input or output/rail | 4 kVeff / 1 min. |
| Temperature coefficient | ≤ 250 ppm/K of final value |
| eClass 5*1 | 27-21-01-20 |
| Current-carrying capacity of cross-connect | ≤ 2 A |
| UNSPSC | 31-12-10-07 |
| Input resistance, voltage | 500 kΩ |
| Operating temperature | 0 °C...55 °C |
| Long specification | Standard signal isolating converter1-channel signal isolating converter in 17.5 mm width with external power supply,for transmitting and isolating analogue DC voltage signals 0...10 V.Add-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 17.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0...10 VOutput 0...10 VTransmission error < 0,2% v. E. Limit frequency 20 kHzAuxiliary power 24 VDC +/- 25 % Power loss approx. 1.3 W Ambient temperature range 0 °C...+55 °CSecure isolation EN 50178, 3-way isolation up to 4 kV AC/DC of all circuits against each otherTest voltage 4 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, CSAType WAS5 VVC HF 0-10/0-10V |
| Input/Output | 0...10 V/ 0...10 V |
| Supply voltage | 24 V DC ± 25 % |
| Step response time | ≤ 40 µs (typ. 30 µs) |
| eClass 8*1 | 27-21-01-20 |
| ETIM 4*0 | EC002653 |
| Mounting rail | TS 35 |
| ETIM 5*0 | EC002653 |
| Insulation voltage | 1.2 kVeff / 5 s |
| Depth (inches) | 4.425 inch |
| Clamping range, rated connection, min | 0.5 mm² |
| Package insert | instruction sheet.pdf |
| eClass 6*2 | 27-21-01-20 |
| Standards | DIN EN 50178, DIN EN 61000-4-2 |
| Depth | 112.4 mm |
| Input voltage | 0...10 V |
| Galvanic isolation | 3-way isolator |
| Storage temperature | -20 °C...85 °C |
| Clearance & creepage distances | ≥ 3 mm |
| Number of inputs | 1 |
| Rated voltage | 300 V |
| Configuration | none |
| MTTF | 409 Years |
| Short specification | Standard signal isolating converter1-channel signal isolating converter in 17.5 mm width, with external power supply,for transmitting and isolating analogue DC voltage signals from 0 to 10 V |
| ETIM 6*0 | EC002653 |
| Clamping range, rated connection | 2.5 mm² |
| Length | 92.4 mm |
| EMC standards | EN 55011, EN 61000-6 |
| eClass 9*0 | 27-21-01-20 |
| Surge voltage category | III |
| Descriptive text accessories | Cross-connector for power supplies and markers – refer to Accessories |
| Clamping range, rated connection, max | 2.5 mm² |
| Type of connection | Screw connection |
| ROHS | Conform |
| RESOURCE TYPE | LINK |
|---|---|
| Datasheets | Analogue Signal Processing |
| QTY | UNIT PRICE | EXT PRICE |
|---|
| Company |
|
|---|---|
| Delivery | 3-5days |
| Costs | $75+ |
| Company |
|
|---|---|
| Delivery | 7-10days |
| Costs | $25+ |