- Home
- Manufacturer
- Hamlin Electronics
Float, Level Sensors

Hamlin Electronics- Float, Level Sensors
Float, Level Sensors - 型号列表
4 parts in total| Mfr Part # | Quantity Available | Price | Lead Time | Subcategory | RoHS | Voltage - Supply | Current Rating (Max) | Packaging | Function | Industry Aliases | Connection Method | Operating Temperature | Tariff No | Output Type | Response Time | Current - Output | Weight | Output Configuration | Diameter - Outside | Length - Lead Wire | Power - Rated | Current - Switching | Voltage - Switching DC | Contact Layout, Typical | Mounting Type | Release Time | Current - Carry | Contact Resistance | Capacitance - Input | Voltage - Breakdown | Insulation Resistance | Termination | Cable Length | Operating Force | Type | Card Standard | Vibration | Operate Time | Power - Max | Load Current | Voltage - Core | Voltage - Breakover | Switch Function/Rating | Length | Thread Size | Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59630-1 T 02 A Liquid Level Sensors Reed Sensors SENSOR, HORIZONTAL, NO Reed Sensor Contact Configuration: 1A SPST-NO Carry Current: 1.2 Amps Max Switching Voltage: 200 VDC Activate Distance: - Termination: Leads Hamlin | 10 | 100: ¥27.132 | 108 Days | Specialized Sensor | RoHS Compliant | 200 V | 500 mA | Bulk | Sensor with integral float magnet attached | 59630-1-T-02-A | Wire | - 40 C | 85365019 | :NO | :1ms | :1.2A | 0.0916 | - | - | - | - | - | - | - | Cable | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
59630-2 T 02 A Liquid Level Sensors Reed Sensors FLOAT SENSOR, NO, HIGH VOLTAGE Reed Sensor Contact Configuration: 1A SPST-NO Carry Current: 1.5Amps Max Switching Voltage: 300 VDC Activate Distance: - Termination: Leads Hamlin | 10 | 100: ¥29.3291 | 108 Days | Specialized Sensor | RoHS Compliant | 300 V | 500 mA | Bulk | Sensor with integral float magnet attached | 59630-2-T-02-A | Cable | - 20 C | 85365019 | :NO | :1ms | :1.5A | 0.01 | Normally Open (NO) | :23.7mm | :300mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
59630-3 T 02 A Liquid Level Sensors Reed Sensors Reed Sensor Contact Configuration: 1C SPDT Carry Current: 1.5Amps Max Switching Voltage: 175 VDC Activate Distance: - Termination: Leads Hamlin | 10 | 100: ¥36.1393 | 108 Days | Specialized Sensor | RoHS Compliant | 175 V | 250 mA | Bulk | Sensor with integral float magnet attached | 59630-3-T-02-A | Cable | - 40 C | - | - | - | - | - | Change Over (CO) | - | - | 5 W | 0.25 AMP | 175 VDC | 1C SPDT | - | 3.0 ms | 1.5Amps | 0.2 ohm | 0.3 pF | 200 VDC | 10^9 ohm | Leads | (11,81) 300 | 50 G | Float Sensor | Reed Sensor | 30 G | 3.0 ms | - | - | - | - | - | - | - | - |
59630-4 T 02 A Liquid Level Sensors Reed Sensors FLOAT SENSOR, NC Reed Sensor Contact Configuration: 1B SPST-NC Carry Current: 1.2 Amps Max Switching Voltage: 200 VDC Activate Distance: - Termination: Leads Hamlin | 10 | 1: ¥21.08 | 108 Days | Specialized Sensor | RoHS Compliant | 200 V | 500 mA | Bulk | Sensor with integral float magnet attached | 59630-4-T-02-A | Cable | - 40 C | 85365019 | :NC | :1ms | :1.2A | 0.0922 | Normally Closed (NC) | :23.7mm | :300mm | :10W | :0.5A | :200 | :1NC | - | - | - | - | - | - | - | - | - | - | - | - | - | - | :10W | :1.2A | :265V | :250VDC | :On-Off | :43.7mm | :M8 x 1.25 | :59630 |