- Home
- Manufacturer
- Schneider Electric SE
Chip Resistors

Schneider Electric SE- Chip Resistors
Chip Resistors - 型号列表
4 parts in total| Mfr Part # | Quantity Available | Price | Lead Time | Subcategory | RoHS | Standards | Certification | Frequency | Isolation | Duty Cycle | Voltage - UL | Power - Output | Voltage Rating | Number of Poles | Duty Cycle (Max) | Current Rating (Max) | Resistance Tolerance | Voltage - Supply (Min) | Power Dissipation (Max) | Voltage - Breakdown (V(BR)GSS) | Weight | 1st Connector | Mounting Type | Terminal Type | Mounting Feature | Torque - Max Momentary (oz-in / mNm) | Type | Usage | Control Method | Measuring Range | Industry Aliases | Device Short Name | Network Technology | Other Specifications | Application Specifics | Shock Resistance | Storage Interface | Ingress Protection | Operating Pressure | Protective Treatment | Vibration Resistance | Operating Temperature | Thermal Current (Ith) | Thermal Resistance @ Natural | Voltage - Supply | Depth | Width | Height | Length | Connector Type | Size / Dimension | Pitch - Connector | Series | Electrical Life | Number of Gangs | Mechanical Life |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GV7RS20 Motor Circuit Breaker GV7RS20 Motor Drives MAN-START 600VAC 20AMP IEC Schneider Electric component GV7RS20: motor circuit breaker GV7-RS - 3 poles 3d - 12...20 A - thermomagnetic trip unit Schneider Electric | 22 | 1: ¥2,582.6264 | 14 Days | Circuit Protection Misc | Compliant | EN 60947-1EN 60947-2EN 60947-4-1IEC 60947-1IEC 60947-2IEC 60947-4-1NF C 63-120NF C 63-650NF C 79-130VDE 0113VDE 0660 | CCCDNVUL | 50/60 Hz conforming to CSA50/60 Hz conforming to CSA C22-2 No 1450/60 Hz conforming to UL | Yes conforming to IEC 60947-1 § 7-1-6 | Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 | 600 V AC 50/60 Hz conforming to CSA C22-2 No 14600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2 | 11 kW at 500 V AC 50/60 Hz11 kW at 660/690 V AC 50/60 Hz15 kW at 660/690 V AC 50/60 Hz9 kW at 400/415 V AC 50/60 Hz9 kW at 500 V AC 50/60 Hz7.5 kW at 400/415 V AC 50/60 Hz | 690 V | 3P | Continuous conforming to IEC 60947-4-1 | 20 A (-25...70 °C) | 0.5 J | 10 KA | 5 W | 8 kV conforming to IEC 60947-2 | 2.01 kg | Power circuit: screw clamp terminal | Fixed | Screw Clamp | HorizontalVertical | 10 N.m - on screw clamp terminal | Bars - width: <= 25 mm - height: 20 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M6Lugs - width: <= 25 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M6 | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 | Rocker lever | GV7R | 785901582977, GV7RS20 | Thermal magnetic circuit breaker | AC | 12 → 20 A | Motor protection | 15 gn 20 ms conforming to IEC 60068-2-27 | -55...95 °C | IP405 open mounted conforming to IEC 60529IP405 with terminal shrouds conforming to IEC 60529 | <= 2000 m | TC | 2.5 gn 25 Hz conforming to IEC 60068-2-6 | -25...70 °C open mounted | 20 A conforming to IEC 60947-4-1 | 12...20 A conforming to IEC 60947-4-1 | - | - | - | - | - | - | - | - | - | - | - | - |
GV7RS220 Motor Circuit Breaker GV7RS220 Motor Drives MAN-START 600VAC 220AMP IEC Schneider Electric component GV7RS220: motor circuit breaker GV7-RS-3 poles 3d - 132...220A - thermomagnetic trip unit Schneider Electric TeSys GV GV7R 系列 132 → 220 A 3极 电动机保护断路器 , 10 kA断开能力, 690 V Schneider Electric | 10 | 1: ¥5,519.70 | 14 Days | Circuit Protection Misc | Compliant | EN 60947-1EN 60947-2EN 60947-4-1IEC 60947-1IEC 60947-2IEC 60947-4-1NF C 63-120NF C 63-650NF C 79-130VDE 0113VDE 0660 | CCCDNVUL | 50/60 Hz conforming to CSA50/60 Hz conforming to IEC 60947-4-150/60 Hz conforming to UL | Yes conforming to IEC 60947-1 § 7-1-6 | Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 | 600 V AC 50/60 Hz conforming to CSA C22-2 No 14600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2 | 110 kW at 400...415 V AC 50/60 Hz110 kW at 500 V AC 50/60 Hz132 kW at 500 V AC 50/60 Hz160 kW at 500 V AC 50/60 Hz160 kW at 660...690 V AC 50/60 Hz200 kW at 660...690 V AC 50/60 Hz90 kW at 400...415 V AC 50/60 Hz | 690 V | 3P | Continuous conforming to IEC 60947-4-1 | 220 A | 0.5 J | 10 KA | 14.5 W | 8 kV conforming to IEC 60947-2 | 2.35 kg | Power circuit: screw clamp terminal | Fixed | Screw Clamp | HorizontalVertical | 15 N.m - on screw clamp terminal | Bars - width: <= 25 mm - height: 20 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M8Lugs - width: <= 25 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M8 | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 | Rocker lever | GV7R | 785901504832, GV7RS220 | Thermal magnetic circuit breaker | AC | 132 → 220 A | Motor protection | 15 gn 20 ms conforming to IEC 60068-2-27 | -55...95 °C | IP405 open mounted conforming to IEC 60529IP405 with terminal shrouds conforming to IEC 60529 | <= 2000 m | TC | 2.5 gn 25 Hz conforming to IEC 60068-2-6 | -25...70 °C open mounted | 220 A conforming to IEC 60947-4-1 | 132...220 A conforming to IEC 60947-4-1 | 10 KA | 126mm | 105mm | 161 mm | 161mm | 螺钉 | 161 x 105 x 126 mm | 35 mm without spreaders45 mm with spreaders | GV7R | 10000 cycles on AC-3 at 440 V In20000 cycles on AC-3 at 440 V In/2 | 25 cyc/h | 20000 cycles |
GV7RS25 Motor Circuit Breaker GV7RS25 Motor Drives MAN-START 600VAC 25AMP IEC Schneider Electric component GV7RS25: motor circuit breaker GV7-RS - 3 poles 3d - 15...25 A - thermomagnetic trip unit Schneider Electric | 22 | 1: ¥2,584.9996 | 14 Days | Circuit Protection Misc | Compliant | EN 60947-1EN 60947-2EN 60947-4-1IEC 60947-1IEC 60947-2IEC 60947-4-1NF C 63-120NF C 63-650NF C 79-130VDE 0113VDE 0660 | CCCDNVUL | 50/60 Hz conforming to CSA50/60 Hz conforming to CSA C22-2 No 1450/60 Hz conforming to UL | Yes conforming to IEC 60947-1 § 7-1-6 | Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 | 600 V AC 50/60 Hz conforming to CSA C22-2 No 14600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2 | 11 kW at 400/415 V AC 50/60 Hz11 kW at 500 V AC 50/60 Hz15 kW at 500 V AC 50/60 Hz15 kW at 660/690 V AC 50/60 Hz9 kW at 400/415 V AC 50/60 Hz18.5 kW at 660/690 V AC 50/60 Hz | 690 V | 3P | Continuous conforming to IEC 60947-4-1 | 25 A (-25...70 °C) | 0.5 J | 10 KA | 5 W | 8 kV conforming to IEC 60947-2 | 2.01 kg | Power circuit: screw clamp terminal | Fixed | Screw Clamp | HorizontalVertical | 10 N.m - on screw clamp terminal | Bars - width: <= 25 mm - height: 20 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M6Lugs - width: <= 25 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M6 | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 | Rocker lever | GV7R | 785901582953, GV7RS25 | Thermal magnetic circuit breaker | AC | 15 → 25 A | Motor protection | 15 gn 20 ms conforming to IEC 60068-2-27 | -55...95 °C | IP405 open mounted conforming to IEC 60529IP405 with terminal shrouds conforming to IEC 60529 | <= 2000 m | TC | 2.5 gn 25 Hz conforming to IEC 60068-2-6 | -25...70 °C open mounted | 25 A conforming to IEC 60947-4-1 | 15...25 A conforming to IEC 60947-4-1 | - | - | - | - | - | - | - | - | - | - | - | - |
GV7RS50 Motor Circuit Breaker GV7RS50 Motor Drives MAN-START 600VAC 50AMP IEC Schneider Electric component GV7RS50: motor circuit breaker GV7-RS - 3 poles 3d - 30...50 A - thermomagnetic trip unit Schneider Electric TeSys GV GV7R 系列 30 → 50 A 3极 电动机保护断路器 , 10 kA断开能力, 690 V Schneider Electric | 10 | 1: ¥4,093.62 | 14 Days | Circuit Protection Misc | Compliant | EN 60947-1EN 60947-2EN 60947-4-1IEC 60947-1IEC 60947-2IEC 60947-4-1NF C 63-120NF C 63-650NF C 79-130VDE 0113VDE 0660 | CCCDNVUL | 50/60 Hz conforming to CSA50/60 Hz conforming to IEC 60947-4-150/60 Hz conforming to UL | Yes conforming to IEC 60947-1 § 7-1-6 | Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 | 600 V AC 50/60 Hz conforming to CSA C22-2 No 14600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2 | 22 kW at 400...415 V AC 50/60 Hz30 kW at 500 V AC 50/60 Hz30 kW at 660...690 V AC 50/60 Hz | 690 V | 3P | Continuous conforming to IEC 60947-4-1 | 50 A | 0.5 J | 10 KA | 5 W | 8 kV conforming to IEC 60947-2 | 2.015 kg | Power circuit: screw clamp terminal | Fixed | Screw Clamp | HorizontalVertical | 10 N.m - on screw clamp terminal | Bars - width: <= 25 mm - height: 20 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M6Lugs - width: <= 25 mm - distance hole to end: <= 10 - thickness: <= 6 mm - screw: M6 | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 | Rocker lever | GV7R | 785901294351, GV7RS50 | Thermal magnetic circuit breaker | AC | 30 → 50 A | Motor protection | 15 gn 20 ms conforming to IEC 60068-2-27 | -55...95 °C | IP405 open mounted conforming to IEC 60529IP405 with terminal shrouds conforming to IEC 60529 | <= 2000 m | TC | 2.5 gn 25 Hz conforming to IEC 60068-2-6 | -25...70 °C open mounted | 50 A conforming to IEC 60947-4-1 | 30...50 A conforming to IEC 60947-4-1 | 10 KA | 111mm | 105mm | 161 mm | 161mm | 螺钉 | 161 x 105 x 111 mm | 35 mm without spreaders45 mm with spreaders | GV7R | 30000 cycles on AC-3 at 440 V In50000 cycles on AC-3 at 440 V In/2 | 25 cyc/h | 50000 cycles |