Teledyne Technologies Incorporated- Accessories
Accessories - 型号列表
323 parts in total| Mfr Part # | Quantity Available | Price | Standard Package | RoHS | Type | Equipment Type | Color | Accessory Type | Bandwidth | Tip Style | Voltage - Max | Design | Packaging | Resistance - Input | Weight | Cable Length | Series | Number of Units | Frequency | Attenuation Value | Probe Type | Input Impedance | Capacitance - Input | Package Quantity | Spg | Rise Time (Typ) | Features | Standard Number | Differential - Input:Output | Includes | Voltage Rating | Product | For Use With/Related Products | Power - Input | Other Names | Power - Output Surge | Voltage - Input (Min) | Core Diameter | Voltage - Limiting (Max) | Size / Dimension | Part # Aliases | Ratio - Input:Output | Length | Attenuation - Typ | Voltage - Input (Max) | Mechanical Life | Turns Ratio - Primary:Secondary | Application Specifics | Specifications | ESD Protection | Current Rating (Max) | Function |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ADP305 Test Probes 1,400 V, 100 MHz High-Volt Probe PROBE HI VOLT DIFFERENTL 100MHZ Oscilloscope probe; Band: ≤100MHz; Attenuator:100:1/1000:1; 2m Differential / High Voltage High Voltage Probe 100 MHz, ADP305, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥12,988.068 | 1 | RoHS Compliant By Exemption | Oscilloscope Probe | High Voltage Probe | - | oscilloscope probe | 20 MHz, 100 MHz | Conical | CAT III 1000V | Differential | - | 8M | 0.3 kg | 78.740" (2000.00mm) | ADP | 1 | ≤100MHz | 100:1, 1000:1 | active, differential, high voltage | 4MΩ/1pF | 6pF | 1 | 1 | - | - | CAT III 1000 V | ±700 V | Case, Clips, Manual, Hook and Loop Strap, Plunger Hook Tip, Spade Terminal | 1400 V | - | - | - | - | - | - | - | - | - | - | - | - | 100:1/1000:1 | 1kV | New At Mouser | - | - | - | - | - | - |
DXC100A Test Probes Passive Dif Probe Pr Selectable, 250 MHz PROBE PASS DIFF 250MHZ 10/100:1 Teledyne LeCroy | 10 | 1: ¥115.396 | 1 | RoHS Compliant By Exemption | Oscilloscope Probe | Passive Probes | Black / Gray, Red / Gray | - | 100 MHz | Conical | 500V | - | - | 1M | - | 47.244" (1200.00mm) | DXC | - | - | 10:1, 100:1 | - | - | 15pF, 26pF | - | - | - | - | - | - | - | 500 V | - | - | - | - | - | - | - | - | - | - | - | - | - | - | New At Mouser | - | - | - | - | - | - |
WSXS-I2CBUS TD Test Accessories - Other I2C BUS TRGR & DECDE OPT FOR WSXS OSC I2CBUS TRIGGER/DECODE-WAVESURFER Benchtop Oscilloscopes I2C BUS TRGR & DECDE OPT FOR WSXS OSC I2C bus trigger, WSXS-I2CBUS TD, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥5,712.00 | 1 | RoHS Compliant By Exemption | Oscilloscope | Test Equipment | - | Software - I2Cbus | - | - | - | - | Bulk | - | - | - | Wavesurf | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Accessories | WaveSurfer Series Oscilloscopes | - | WSXSI2CBUSTD | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
WSXS-HARDCASE Instrument Protection and Storage HARD CARRYING CASE WSX CASE HARD CARRY WAVESURFER-MXS-B Teledyne LeCroy | 10 | 1: ¥4,658.00 | 1 | Not Applicable | Oscilloscope | Carrying Case | Black | Hard Case | - | - | - | - | Bulk | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Accessories | WaveSurfer Series Oscilloscopes | - | WSXSHARDCASE | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
PP016 Test Probes 10:1 10MOHM 300MHZ PASV PRB (WA) PASS PROBE 10:1 300MHZ-WAVEACE Oscilloscope probe; Band: ≤300MHz; Trans:10:1; Type: passive sale Voltage Probe 1:1 / 10:1 300 MHz, PP016, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥1,326.00 | 1 | RoHS Compliant By Exemption | Passive | Passive Probes | Black | oscilloscope probe | 10MHz, 300MHz | Sharp Point | 600V (DC + AC Peak) | Voltage | Bulk | 1M, 10M | 0.1 kg | 47.244" (1200.00mm) | WaveAce | 1 | ≤300MHz | 1:1, 10:1 | passive | 12 | 46pF, 12pF | - | - | - | - | - | - | Adjustment Tool, BNC Adapter, Code Rings, Ground Attachment and Lead, IC Test Tip, Replacement Tip, Sprung Hook | 600 V | - | - | - | - | - | - | - | 600 | - | STATION WAVE | 1:1 | 1200 mm | - | - | - | 10:1 | - | - | - | - | - |
WA-SOFTCASE Instrument Protection and Storage SOFT CARRYING CASE FOR WA OSC CASE SOFT CARRYING FOR WAVEACE Toolbag; Application: LC-ACE Teledyne LeCroy | 10 | 1: ¥714.00 | 1 | Not Applicable | Oscilloscope | Carrying Case | Black | Carrying Case, Soft | - | - | - | - | Bulk | - | 0.47 kg | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | - | Accessories | WaveAce Series Oscilloscopes | - | WASOFTCASE | - | - | - | - | - | STATION WAVE | - | - | - | - | - | - | LC-ACE | - | - | - | - |
AP015 Test Probes 50MHZ CUR PRB PROBE CURRENT 30A 50MHZ Oscilloscope probe; Band: ≤50MHz; Rise time: ≤3,5ns; I AC:30A Current Current Probe 30 A 50 MHz, AP015, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥23,052.00 | 1 | RoHS Compliant By Exemption | Current Probe | Current Probes | Black | oscilloscope probe | 50MHz | Flat | CAT I 300V, CAT II 150V | Current | Bulk | - | 300g | 78.740" (2000.00mm) | AP | 1 | ≤50MHz | - | current | - | - | 1 | 1 | ≤3,5ns | 2 meters | CAT I 300 V | - | - | - | - | - | from oscilloscope | - | 30 | 30A | 5 | - | - | - | - | 78.740" (2000.00mm) | - | - | - | - | - | - | - | - | - |
ZD200 Test Probes 200MHZ 3.5 PF 1MOHM ACTV DIFF PRB +-20V PROBE ACT DIF 200MHZ 3.5PF 1MOHM Oscilloscope probe; Band: ≤200MHz; Rise time:1,75ns Differential Differential Probe Kit 200 MHz, ZD200, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥11,798.068 | 1 | RoHS Compliant By Exemption | Active Differential | Differential Probes | Black and Red | oscilloscope probe | 200MHz | Multi Point | - | Differential | Bulk | 1M | 1.36 kg | - | - | 1 | ≤200MHz | 10:1 | active, differential | 1MΩ/3,5pF | 3.5pF | 1 | 1 | 1,75ns | 200 MHz bandwidth | - | ±20 V | Clips, Grabbers, Leads, Manual, Pin Sets, Tip | - | - | - | - | - | - | - | - | 20 | - | - | - | - | - | - | - | - | - | - | - | - | - |
WJ-CASE Instrument Protection and Storage CARRY CASE & FRONT COVER FOR WAVEJET CASE&FRONT CVR FOR WAVEJET 300A Teledyne LeCroy | 10 | 1: ¥1,190.00 | 1 | Not Applicable | Oscilloscope | Carrying Case | Black | Carrying Case | - | - | - | - | Bulk | - | - | - | - | - | - | - | - | - | - | - | - | - | Protective Front Cover | - | - | - | - | Accessories | WaveJet Series Oscilloscopes | - | WJCASE | - | - | - | - | - | - | - | - | - | - | - | - | - | Protective Front Cover | - | - | - |
ZD500 Test Probes 500MHZ 1.0 PF ACTV DIFF PRB +-9V PROBE ACT DIFF 500MHZ 1PF +/-8V Differential Differential Probe Kit 500 MHz, ZD500, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥21,433.736 | 1 | RoHS Compliant By Exemption | Active Differential | Differential Probes | Black | - | 500MHz | Multi Point | 8V | Differential | Bulk | 1M | - | - | - | - | - | 10:1 | - | 1 | 1pF | - | - | 0.65 | 500 MHz bandwidth | - | ±8 V | Adapters, Calibration Fixture, Connector, Grabbers, Grounds, Manual, Tips | - | - | - | - | - | - | - | - | 16 | - | - | - | - | - | - | - | - | - | - | - | - | - |
CP031 Test Probes 30A 100MHZ CUR PRB PROBE CURRENT 30A 100MHZ Oscilloscope probe; Band: ≤50MHz; Rise time: ≤3,5ns; I AC:30A Current Current Probe 30 A 100 MHz, CP031, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥30,532.136 | 1 | RoHS Compliant By Exemption | Current Probe | Current Probes | Gray | oscilloscope probe | 100MHz | Flat | CAT I 300V | Current | Bulk | - | 240g | 59.055" (1500.00mm) | - | 1 | ≤50MHz | - | current | - | - | 1 | 1 | ≤3,5ns | 1.5 meters | CAT I 300 V | - | - | - | - | - | from oscilloscope | - | 30 | 30A | 5 | - | 175 x 40 x 18mm | - | - | - | - | - | - | - | - | - | - | - | - |
ZD1000 Test Probes 1GHZ 1.0 PF ACTV DIFF PRB +-9V PROBE ACT DIFF 1GHZ 1PF +/-8V Differential Differential Probe Kit 1000 MHz, ZD1000, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥29,301.336 | 1 | RoHS Compliant By Exemption | Active Differential | Differential Probes | Black | - | 1GHz | Multi Point | 8V | Differential | Bulk | 1M | - | - | - | - | - | 10:1 | - | 1 | 1pF | - | - | 0.375 | 1000 MHz bandwidth | - | ±8 V | Adapters, Calibration Fixture, Connector, Grabbers, Grounds, Manual, Tips | - | - | - | - | - | - | - | - | 16 | - | - | - | - | - | - | - | - | - | - | - | - | - |
CP500 Test Probes 500A DC/AC CUR PRB 2MHZ PROBE CURRENT 500A DC/AC 2MHZ Oscilloscope probe; Band: ≤2MHz; Rise time: ≤175ns; I AC:500A Current Current Probe 500 A 2 MHz, CP500, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥32,096.204 | 1 | RoHS Compliant By Exemption | Current Probe | Current Probes | Gray | oscilloscope probe | 2MHz | Flat | CAT II 600V, CAT III 300V | Current | Bulk | - | 630g | 236.220" (6000.00mm) | - | 1 | ≤2MHz | - | current | - | - | 1 | 1 | ≤175ns | 6 meters | CAT I 600 V | - | - | - | - | - | from oscilloscope | - | 500 | 500A | 20 | - | 176 x 69 x 27mm | - | - | - | - | - | - | - | - | - | - | - | - |
WSXS-SOFTCASE Instrument Protection and Storage SOFT CARRYING CASE WSX CASE SOFT CARRY WAVESURFER-MXS-B Teledyne LeCroy | 10 | 1: ¥1,768.00 | 1 | Not Applicable | Oscilloscope | Carrying Case | Black | Carrying Case, Soft | - | - | - | - | Bulk | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Accessories | WaveSurfer Series Oscilloscopes | - | WSXSSOFTCASE | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CP150 Test Probes 150A DC/AC CUR PRB PROBE CURRENT 150 AMP DC/AC Oscilloscope probe; Band: ≤100MHz; Rise time: ≤35ns; I AC:150A Current Current Probe 150 A 10 MHz, CP150, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥28,492.00 | 1 | RoHS Compliant By Exemption | Current Probe | Current Probes | Gray | oscilloscope probe | 10MHz | Flat | CAT II 600V, CAT III 300V | Current | Bulk | - | 500g | 78.740" (2000.00mm) | - | 1 | ≤100MHz | - | current | - | - | 1 | 1 | ≤35ns | 2 meters | CAT I 600 V | - | - | - | - | - | from oscilloscope | - | 150 | 150A | 20 | - | 176 x 69 x 27mm | - | - | - | - | - | - | - | - | - | - | - | - |
AP031 Test Probes Differential Probe 700 V, 15 MHz PROBE HI VOLT DIFFERENTL 15MHZ Differential / High Voltage High Voltage Probe 10:1 / 100:1 15 MHz, AP031, Teledyne LeCroy Teledyne LeCroy | 14 | 1: ¥109.072 | 1 | RoHS Compliant By Exemption | Voltage Probe, Differential | Oscilloscopes | Black, Red | - | 15MHz | Hook | 700V | Differential | - | 4M | - | - | ADP | - | - | 10:1, 100:1 | - | 4 | - | - | - | - | - | - | ±70 V @ 1:10 / ±700 V @ 1:100 (DC+peak AC) | - | 700 V | - | - | 4 x LR6/AA | - | - | - | - | - | - | STATION WAVE | 10:1 | 6.6 in | - | - | - | - | - | - | CAT III | 60 mA | Used where electrical signals must be measured relative to a floating voltage different to the oscilloscope ground potential |
WSXS-POUCH Instrument Protection and Storage WSXs Accessory Pouch WSXS ACCESSORY POUCH Teledyne LeCroy | 10 | 1: ¥408.00 | 1 | RoHS Compliant By Exemption | Oscilloscope | WaveSurfer Series Oscilloscopes | Black | Carrying Case, Soft | - | - | - | - | - | - | - | - | Wavesurf | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Accessories | WaveSurfer Series Oscilloscopes | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CP030 Test Probes 30A, 50MHz Current Probe PROBE CURRENT 30A 50MHZ Oscilloscope probe; Band: ≤50MHz; Rise time: ≤7ns; I AC:30A; 1.5m Current Current Probe 30 A 50 MHz, CP030, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥27,454.388 | 1 | RoHS Compliant By Exemption | Current Probe | Current Probes | Gray | oscilloscope probe | 50MHz | Multi Point | CAT I 300V | Current | - | 1M | 240g | 59.055" (1500.00mm) | CP | 1 | ≤50MHz | - | current | - | - | 1 | 1 | ≤7ns | - | CAT I 300 V | - | - | 300 V | - | - | from oscilloscope | - | 30 | 30A | 5 | - | 175 x 40 x 18mm | - | - | - | - | - | - | - | - | - | - | - | - |
ADP300 Test Probes Differential Probe 1,400 V, 20 MHz PROBE HI VOLT DIFFERENTL 20MHZ Oscilloscope probe; Band: ≤20MHz; Attenuator:100:1/1000:1; 2m Differential / High Voltage High Voltage Probe 20 MHz, ADP300, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥10,744.068 | 1 | RoHS Compliant By Exemption | Voltage Probe, Differential | Active Probe | - | oscilloscope probe | 20MHz | Conical | CAT III 1000V | Differential | - | 8M | 0.96 kg | 78.740" (2000.00mm) | ADP | 1 | ≤20MHz | 100:1, 1000:1 | active, differential, high voltage | 4MΩ/1pF | 6pF | 1 | 1 | - | - | CAT III 1000 V | ±700 V | Manual, Hook and Loop Strap, Plunger Hook Tip | 1.4 kV | - | - | - | - | - | - | - | - | - | - | - | - | 100:1/1000:1 | 1kV | - | - | - | - | - | - | - |
AP033 Test Probes 500 MHz Differential Probe PROBE DIFFERENTIAL 500MHZ Differential Differential Probe 1:10 / 1:1 / 10:1 / 100:1 500 MHz, AP033, Teledyne LeCroy Teledyne LeCroy | 10 | 1: ¥65,518.272 | 1 | RoHS Compliant By Exemption | Active Differential | Active Probe | Gray | - | 500MHz | Multi Point | CAT I 42.4V | Differential | - | 2M | - | 42.000" (1066.80mm) | AP | - | - | 1:1, 10:1 | - | 2 | 2.7pF, 1.2pF | - | - | - | - | - | ±40 V | AC Coupler, Accessory Kit, Attenuators, Case, Manual | - | - | - | - | - | - | - | - | - | - | - | 1:10 | - | - | - | - | - | - | - | - | - | - |