ONEIC.US
Weidmüller Holding AG & Co. KG

Weidmüller Holding AG & Co. KG- Video Pre-Amplifiers

Weidmüller is a German pioneer in industrial connectivity, founded in 1948 and headquartered in Detmold, Germany. The company specializes in enabling reliable transmission of power, signals, and data in automation and industrial environments. Its core product portfolio includes a comprehensive range of terminal blocks, printed circuit board connectors, and heavy-duty connectors. Weidmüller also offers electronic interface modules, relay modules, and surge protection devices to complete the connectivity chain. Advanced sensor-actuator cabling and industrial Ethernet solutions underscore its move into smart manufacturing. The group provides high-quality hand and power tools, as well as customized enclosures and marking systems, to support installation and maintenance. With over 80 country representations and manufacturing facilities worldwide, Weidmüller serves customers in machinery, process, and building automation. The company holds a leading global market share in terminal block technology and is recognized for setting industry standards in safe and efficient electrical connections. Continuous focus on sustainable innovation drives its development of solutions for future industrial challenges. In 2013, the group employed 4,600 people, a number that has since grown with its expanding global footprint.

03

Video Pre-Amplifiers - 型号列表

58 parts in total

Type

GTIN (EAN)

Firmware Version

Other Names

Number of Ports

Current - Average Rectified (Io)

Weight

LED

Voltage - Supply

IEC 61000-4-2

Declaration of Conformity

Width

Plunger Size

Width (Inches)

Switch Type

Fiber Ports

Security Features

Overload Protection

Height

Stud/Tab Size

Height (Inches)

Other Specifications

Depth

Mounting Type

Depth (Inches)

Housing Material

ETIM 6*0

Connection Type

Operate Time

ET (Volt-Time)

Operating Temperature

Wavelength

Sensitivity

Mode

Product Type

Mfr Part #Quantity AvailablePriceStandard PackageRoHSIEC StandardIEC 61000-4-2Protection FeaturesDeclaration of ConformityLEDFrequencyDelay TimeVoltage - SupplyReverse Polarity ProtectionCurrent - Average Rectified (Io)DepthWidthHeightWeightPlunger SizeMounting TypeStud/Tab SizeDepth (Inches)Width (Inches)Height (Inches)Operating ForceHousing MaterialPackage QuantityTypeSeriesETIM 6*0GTIN (EAN)Switch TypeConnection TypeNumber of PortsFirmware VersionOther SpecificationsWith Auto Flow ControlVibrationOperate TimeET (Volt-Time)Humidity RangeStorage InterfaceIngress ProtectionOperating TemperatureSecurity FeaturesSwitching EnergyShipping InfoOther NamesOverload ProtectionFiber PortsWavelengthSensitivityModeContact FormFWFT SupportClosure SystemDistanceSignal LinesSensing DistanceOperating SystemProduct TypePoE PortsVoltage RatingBus ConnectionEngineering DataFor Use With/Related ProductsContact SizeVgs(th) (Max) @ IdProgram Memory SizeVoltage - Input (Min)Cable GroupNumber of Cable PairsProtocolQuantityFile TypeTool TypeManual OverrideControl Interface
1240850000
1240850000

NETWORK SWITCH Ethernet Switch 5-Port 10Mbps/100Mbps

Weidmuller

101: ¥1,719.53641Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port)19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for flow controlAvailable0.1 A at 24 V70 mm30 mm115 mm175 g512 KbitMounting rail1 K2.756 inch1.181 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL05T-5TX*EC00259840501180286831x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block5x RJ45Network switch, unmanaged, Fast Ethernet, Number of ports: 5x RJ45, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-BL05T-5TX1.1 A-----------------------------
1286560000
1286560000

NETWORK SWITCH

Weidmuller

101: ¥1,253.9881Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port)19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for flow controlAvailable0.13 A at 24 V70 mm50 mm115 mm275 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL08T-8TX*EC00073440501180769671x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block8x RJ45Network switch, unmanaged, Fast Ethernet, Number of ports: 8x RJ45, IP30, -40 °C...75 °Caccording to IEC 60068-2-32IEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-BL08T-8TX1.1 A-----------------------------
1286550000
1286550000

NETWORK SWITCH

Weidmuller

101: ¥1,677.8321Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.11 A at 24 V70 mm30 mm115 mm175 g512 KbitMounting rail1 K2.756 inch1.181 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL05T-4TX-1SC*EC00073440501180774211x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block4 x RJ45, 1 * SC Multi-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 4 x RJ45, 1 * SC Multi-mode, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-BL05T-4TX1.1 A100BaseFX ports (SC connector), Multimode1,300 nm-32 dBm-20 dBm---6 dBm4 km (62.5/125 μm multi-mode cable), 5 km (50/125 μm multi-mode cable)---------------------
1286540000
1286540000

NETWORK SWITCH

Weidmuller

101: ¥1,677.8321Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.11 A at 24 V70 mm30 mm115 mm175 g512 KbitMounting rail1 K2.756 inch1.181 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL05T-4TX-1ST*EC00073440501180769811x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block4 x RJ45, 1 * ST Multi-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 4 x RJ45, 1 * ST Multi-mode, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GL-1.1 A100BaseFX ports (ST connector), Multimode1,300 nm-32 dBm-20 dBm---6 dBm4 km (62.5/125 μm multi-mode cable), 5 km (50/125 μm multi-mode cable)---------------------
1240930000
1240930000

NETWORK SWITCH

Weidmuller

50001: ¥2,656.421Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.22 A at 24 V70 mm50 mm115 mm275 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL08-6TX-2ST*EC00259840501180287441x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block6x RJ45, 2 * ST Multi-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 6x RJ45, 2 * ST Multi-mode, IP30, -10 °C...60 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0660 °CUL508Store and ForwardDNV, GL-1.1 A100BaseFX ports (ST connector), Multimode1,300 nm-32 dBm-20 dBm---6 dBm4 km (62.5/125 μm multi-mode cable), 5 km (50/125 μm multi-mode cable)---------------------
1241250000
1241250000

NETWORK SWITCH

Weidmuller

101: ¥2,597.601Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_005.pdfPWR1, PWR2, FAULT, 10/100/1000M19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3x for flow controlAvailable0.20 A at 24 V105 mm35 mm130 mm290 g1,088 KbitMounting rail, Panel (with optional mounting kit)8 K4.134 inch1.378 inch5.118 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-BL05-5GT*EC0025984050118029277Port surveillance, Broadcast storm protection enable/disable, Enable/disable jumbo frame support1 removable 6-pin terminal block5 * RJ45 10/100/1000BaseT(X)Network switch, unmanaged, Gigabit Ethernet, Number of ports: 5 * RJ45 10/100/1000BaseT(X), IP30, 0 °C...60 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0660 °CUL508Store and ForwardDNV, GLIE-SW-BL05-5GT-----1 relay output with a current capacity of 1 A at 24 V DCup to 9.6 KB-----2435400000-----------------
1241380000
2
1241380000

NETWORK SWITCH Weidmuller 以太网 非托管型以太网交换机, 使用于以太网网络

Weidmuller

101: ¥2,571.2161Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), level 4, EN 61000-4-5 (surge), level 4, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8IP30DE_PN4800_160418_006.pdfPWR1, PWR2, 10/100M (TP-Port), PoE19-17-01-065 yearsIEEE 802.3af for Power-over-Ethernet, IEEE 802.3at for Power-over-Ethernet, IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for flow controlAvailable5.5 A with 24 V DC (at full PoE+ load), 2.6 A with 48 V DC (at full PoE+ load)70 mm50 mm115 mm375 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL06-2TX-4POE*EC00259840501180290931x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block2 * RJ45 10/100 BaseT(X), 4 * RJ45 10/100 BaseT(X) PoE+Network switch, unmanaged PoE, Fast Ethernet, Number of ports: 2 * RJ45 10/100 BaseT(X), 4 * RJ45 10/100 BaseT(X) PoE+, IP30, 0 °C...60 °Caccording to IEC 60068-2-32IEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0660 °CUL60950-1, UL508Store and Forward-IE-SW-BL06-2TXExisting------------V-, V-, V+, V+ for pin 1, 2, 3, 6 (endspan, MDI-X alternative A)24/48 V DC以太网EPLAN, Zuken E3.S以太网网络------------
1240920000
1240920000

NETWORK SWITCH

Weidmuller

101: ¥2,779.2281Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.22 A at 24 V70 mm50 mm115 mm275 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL08T-6TX-2SC*EC00259840501180289281x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block6x RJ45, 2 * SC Multi-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 6x RJ45, 2 * SC Multi-mode, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-BL08T-6TX1.1 A100BaseFX ports (SC connector), Multimode1,300 nm-32 dBm-20 dBm---6 dBm4 km (62.5/125 μm multi-mode cable), 5 km (50/125 μm multi-mode cable)---------------------
1286530000
1286530000

NETWORK SWITCH

Weidmuller

101: ¥2,803.4361Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.11 A at 24 V70 mm30 mm115 mm175 g512 KbitMounting rail1 K2.756 inch1.181 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL05T-4TX-1SCS*EC00073440501180772301x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block4 x RJ45, 1 * SC Single-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 4 x RJ45, 1 * SC Single-mode, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GL-1.1 A100BaseFX ports (SC connector), Singlemode1,310 nm-34 dBm-5 dBm----29 dB40 km (9/125 μm single-mode cable)-3 dBm------------------
1286570000
1286570000

NETWORK SWITCH

Weidmuller

101: ¥2,827.101Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.22 A at 24 V70 mm50 mm115 mm275 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL08T-6TX-2ST*EC00073440501180769741x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block6x RJ45, 2 * ST Multi-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 6x RJ45, 2 * ST Multi-mode, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GL-1.1 A100BaseFX ports (ST connector), Multimode1,300 nm-32 dBm-20 dBm---6 dBm4 km (62.5/125 μm multi-mode cable), 5 km (50/125 μm multi-mode cable)---------------------
1240950000
1240950000

NETWORK SWITCH

Weidmuller

101: ¥2,900.3361Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.17 A at 24 V70 mm50 mm115 mm275 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL08-7TX-1SCS*EC00259840501180288501x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block7x RJ45, 1 * SC Single-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 7x RJ45, 1 * SC Single-mode, IP30, -10 °C...60 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0660 °CUL508Store and ForwardDNV, GLIE-SW-BL08-7TX1.1 A100BaseFX ports (SC connector), Singlemode1,310 nm-34 dBm-5 dBm----29 dB40 km (9/125 μm single-mode cable)-3 dBm------------------
1286850000
1286850000

NETWORK SWITCH

Weidmuller

101: ¥2,985.4721Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_005.pdfPWR1, PWR2, FAULT, 10/100/1000M19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3x for flow controlAvailable0.20 A at 24 V105 mm35 mm130 mm290 g1,088 KbitMounting rail, Panel (with optional mounting kit)8 K4.134 inch1.378 inch5.118 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-BL05T-5GT*EC0007344050118077575Port surveillance, Broadcast storm protection enable/disable, Enable/disable jumbo frame support1 removable 6-pin terminal block5 * RJ45 10/100/1000BaseT(X)Network switch, unmanaged, Gigabit Ethernet, Number of ports: 5 * RJ45 10/100/1000BaseT(X), IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-BL05T-5GT-----1 relay output with a current capacity of 1 A at 24 V DCup to 9.6 KB-----2435410000-----------------
1286580000
1286580000

NETWORK SWITCH

Weidmuller

101: ¥3,190.9681Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8, EN 61000-4-11IP30DE_PN4800_160418_001.pdfPWR1, PWR2, 10/100M (TP-Port), 100M (fibre-optic port).19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.17 A at 24 V70 mm50 mm115 mm275 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL08T-7TX-1SCS*EC00073440501180772471x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block7x RJ45, 1 * SC Single-modeNetwork switch, unmanaged, Fast Ethernet, Number of ports: 7x RJ45, 1 * SC Single-mode, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-BL08T-7TX1.1 A100BaseFX ports (SC connector), Singlemode1,310 nm-34 dBm-5 dBm----29 dB40 km (9/125 μm single-mode cable)-3 dBm------------------
1286920000
1286920000

NETWORK SWITCH

Weidmuller

101: ¥3,226.0561Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), level 4, EN 61000-4-5 (surge), level 4, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8IP30DE_PN4800_160418_006.pdfPWR1, PWR2, 10/100M (TP-Port), PoE19-17-01-065 yearsIEEE 802.3af for Power-over-Ethernet, IEEE 802.3at for Power-over-Ethernet, IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for flow controlAvailable5.5 A with 24 V DC (at full PoE+ load), 2.6 A with 48 V DC (at full PoE+ load)70 mm50 mm115 mm375 g512 KbitMounting rail1 K2.756 inch1.969 inch4.528 inchaccording to IEC 60068-2-27AluminiumHardware Installation GuideIE-SW-BL06T-2TX-4POE*EC00073440501180779261x for enabling/disabling the broadcast storm protection1 removable 4-pin terminal block2 * RJ45 10/100 BaseT(X), 4 * RJ45 10/100 BaseT(X) PoE+Network switch, unmanaged PoE, Fast Ethernet, Number of ports: 2 * RJ45 10/100 BaseT(X), 4 * RJ45 10/100 BaseT(X) PoE+, IP30, -40 °C...75 °Caccording to IEC 60068-2-32IEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL60950-1, UL508Store and Forward-IE-SW-BL06T-2TXExisting------------V-, V-, V+, V+ for pin 1, 2, 3, 6 (endspan, MDI-X alternative A)24/48 V DC---------------
1241270000
1241270000

NETWORK SWITCH

Weidmuller

101: ¥5,779.49681Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_005.pdfPWR1, PWR2, FAULT, 10/100/1000M19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3x for flow controlAvailable0.32 A at 24 V105 mm53.6 mm135 mm850 g1,408 KbitMounting rail, Panel (with optional mounting kit)8 K4.134 inch2.11 inch5.315 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-VL08-8GT*EC0025984050118029284Port surveillance, Broadcast storm protection enable/disable, Enable/disable jumbo frame support1 removable 6-pin terminal block8 * RJ45 10/100/1000BaseT(X)Network switch, unmanaged, Gigabit Ethernet, Number of ports: 8 * RJ45 10/100/1000BaseT(X), IP30, 0 °C...60 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0660 °CUL508Store and ForwardDNV, GLIE-SW-VL08-8GT-----1 relay output with a current capacity of 1 A at 24 V DCup to 9.6 KB-----------------------
1241280000
1241280000

NETWORK SWITCH

Weidmuller

101: ¥4,353.4961Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_005.pdfPWR1, PWR2, FAULT, 10/100/1000M19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3z for 1000BaseX, IEEE 802.3x for flow controlAvailable0.34 A at 24 V105 mm53.6 mm135 mm850 g1,408 KbitMounting rail, Panel (with optional mounting kit)8 K4.134 inch2.11 inch5.315 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-VL08-6GT-2GS*EC0025984050118029062Port surveillance, Broadcast storm protection enable/disable, Enable/disable jumbo frame support1 removable 6-pin terminal block6 * RJ45 10/100/1000BaseT(X), 2 * combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP)Network switch, unmanaged, Gigabit Ethernet, Number of ports: 6 * RJ45 10/100/1000BaseT(X), 2 * combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP), IP30, 0 °C...60 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0660 °CUL508Store and ForwardDNV, GLIE-SW-VL08-6GT-100/1000Base SFP Slot---1 relay output with a current capacity of 1 A at 24 V DCup to 9.6 KB-----------------------
1286860000
1286860000

NETWORK SWITCH

Weidmuller

101: ¥4,340.0321Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_005.pdfPWR1, PWR2, FAULT, 10/100/1000M19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3x for flow controlAvailable0.32 A at 24 V105 mm53.6 mm135 mm850 g1,408 KbitMounting rail, Panel (with optional mounting kit)8 K4.134 inch2.11 inch5.315 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-VL08T-8GT*EC0007344050118077803Port surveillance, Broadcast storm protection enable/disable, Enable/disable jumbo frame support1 removable 6-pin terminal block8 * RJ45 10/100/1000BaseT(X)Network switch, unmanaged, Gigabit Ethernet, Number of ports: 8 * RJ45 10/100/1000BaseT(X), IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-VL08T-8GT-----1 relay output with a current capacity of 1 A at 24 V DCup to 9.6 KB-----------------------
1286590000
1286590000

NETWORK SWITCH

Weidmuller

101: ¥4,820.2481Lead free / RoHS Compliant19-17-01-06FCC Part 15, CISPR (EN55022) Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_002.pdfPWR1, PWR2, FAULT, 10/100M (TP-Port)19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3x for flow controlAvailable0.27 A at 24 V105 mm80.5 mm135 mm1,140 g1.25 MbitMounting rail4 K4.134 inch3.169 inch5.315 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-VL16T-16TX*EC0007344050118077414Port surveillance, Broadcast storm protection enable/disable1 removable 6-pin terminal block16x RJ45Network switch, unmanaged, Fast Ethernet, Number of ports: 16x RJ45, IP30, -40 °C...75 °Caccording to IEC 60068-2-32IEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6MIL-HDBK-217F, GB 25°CEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °C-Store and ForwardDNV, GLIE-SW-VL16T-16TX1.6 A-----------------1 relay output with a current capacity of 1 A at 24 V DC-----------
1240940000
2
1240940000

NETWORK SWITCH Weidmuller 以太网 以太网交换机, 使用于以太网网络

Weidmuller

101: ¥7,291.83451Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3, EN 61000-4-8IP30DE_PN4800_160418_004.pdfPWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, 10/100M (TP-Port)19-17-01-065 years24 V DC, 12 to 45 V DC, 2 redundant inputsAvailable0.26 A bei 24 V105 mm53.6 mm135 mm890 g1 MbitMounting rail8 K4.134 inch2.11 inch5.315 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-VL08MT-8TX*EC0025984050118028676Turbo-Ring, Master, Coupler, Reserve1 removable 6-pin terminal block8x RJ45Network switch, managed, Fast Ethernet, Number of ports: 8x RJ45, IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0025985 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508, UL60950-1, CSA C22.2 No. 60950-1, EN60950-1-DNV, GLIE-SW-VL08MT-8TXExisting----1 relay output with a current capacity of 1 A at 24 V DC---------以太网EPLAN, Zuken E3.S以太网网络-4,094Version 3.3.16125664IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, TFTP, SNTP, SMTP, RARP, RMON, HTTP, Telnet, Syslog, DHCP option 66/67/82, BootP, LLDP, PROFINET, EtherNet/IP, Modbus/TCP, IPv64GSDML IE-SW-VL08M-SeriesManaged Switch Configuration UtilityManualRS-232
1286870000
1286870000

NETWORK SWITCH

Weidmuller

101: ¥5,067.9721Lead free / RoHS Compliant19-17-01-06FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-4-2 (ESD), Stage 3, EN 61000-4-3 (RS), Stage 3, EN 61000-4-4 (EFT), Stage 3, EN 61000-4-5 (surge voltage), Stage 3, EN 61000-4-6 (CS), Stage 3IP30DE_PN4800_160418_005.pdfPWR1, PWR2, FAULT, 10/100/1000M19-17-01-065 yearsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) und 100BaseFX, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3z for 1000BaseX, IEEE 802.3x for flow controlAvailable0.34 A at 24 V105 mm53.6 mm135 mm630 g1,408 KbitMounting rail, Panel (with optional mounting kit)8 K4.134 inch2.11 inch5.315 inchaccording to IEC 60068-2-27metalHardware Installation GuideIE-SW-VL08T-6GT-2GS*EC0007344050118077759Port surveillance, Broadcast storm protection enable/disable, Enable/disable jumbo frame support1 removable 6-pin terminal block6 * RJ45 10/100/1000BaseT(X), 2 * combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP)Network switch, unmanaged, Gigabit Ethernet, Number of ports: 6 * RJ45 10/100/1000BaseT(X), 2 * combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP), IP30, -40 °C...75 °CUL/cUL, Class I, Division 2, Groups A, B, C and D, ATEX Zone 2 Ex nA nC IIC T4 GcIEEE 802.3x flow control, Back pressure flow controlaccording to IEC 60068-2-6Telcordia (Bellcore), GBEC0007345 to 95 % (non-condensing)-40 °C19-17-01-0675 °CUL508Store and ForwardDNV, GLIE-SW-VL08T-6GT-100/1000Base SFP Slot---1 relay output with a current capacity of 1 A at 24 V DCup to 9.6 KB-----------------------
Page 1 / 3
1