ONEIC.US
Weidmüller Holding AG & Co. KG

Weidmüller Holding AG & Co. KG- Current Transducers

Weidmüller is a German pioneer in industrial connectivity, founded in 1948 and headquartered in Detmold, Germany. The company specializes in enabling reliable transmission of power, signals, and data in automation and industrial environments. Its core product portfolio includes a comprehensive range of terminal blocks, printed circuit board connectors, and heavy-duty connectors. Weidmüller also offers electronic interface modules, relay modules, and surge protection devices to complete the connectivity chain. Advanced sensor-actuator cabling and industrial Ethernet solutions underscore its move into smart manufacturing. The group provides high-quality hand and power tools, as well as customized enclosures and marking systems, to support installation and maintenance. With over 80 country representations and manufacturing facilities worldwide, Weidmüller serves customers in machinery, process, and building automation. The company holds a leading global market share in terminal block technology and is recognized for setting industry standards in safe and efficient electrical connections. Continuous focus on sustainable innovation drives its development of solutions for future industrial challenges. In 2013, the group employed 4,600 people, a number that has since grown with its expanding global footprint.

03

Current Transducers - 型号列表

5 parts in total

Operating Temperature

Indicator

Weight

Type

GTIN (EAN)

Specifications

Firmware Version

RoHS

Voltage - Supply

Frequency

Hysteresis

Settling Time

Voltage Rating

Voltage - Breakdown

Voltage - Input (Min)

Impulse Discharge Current (8/20us)

Width

Length

Width (Inches)

Length (Inches)

Function

Description

Distance

Operational Life

Ingress Protection

Temperature Coefficient

Number of Inputs

Mfr Part #Quantity AvailablePriceStandard PackageRoHSSeriesOperating TemperatureVoltage - SupplyDeclaration of ConformityFrequencyIndicatorRange deg/sDepthWidthLengthWeightConnector TypeDepth (Inches)Width (Inches)Length (Inches)Package QuantityTypeGTIN (EAN)DescriptionSpecificationsFirmware VersionIngress ProtectionStandardsIEC 61000-4-2Standard NumberAccuracyIsolationHysteresisResponse TimeSettling TimeCurrent - TestVoltage RatingVoltage - BreakdownVoltage - Input (Min)Voltage - Switching ACImpulse Discharge Current (8/20us)Mounting RailsETIM 6*0FunctionConfigurationOther SpecificationsDistanceET (Volt-Time)Operational LifeTemperature CoefficientNumber of InputsOther NamesInput TypeInput RangeOutput TypeSensor TypeOutput RangeSignal ConditioningMounting TypeStandard PackVoltage - MaxCurrent - SwitchingSafety CategoryCurrentLoad CurrentOutput SignalCurrent - OutputNumber of OutputsCurrent - Input Bias
7940016563
7940016563

1 TX+4-20MA/4-20MA -EA SIGNAL CONVERTER/DISCONNECTOR

weidmuller

50001: ¥2,590.9361Lead free / RoHS Compliant*---------------------------------------------------------------
8473010000
8473010000

MCZ PT100/3 CLP 0...200C TS 35 -EA CONDITIONER SIGNAL ANALOG 4-20MA Temp transducer for Pt100,0 to 200 deg C

weidmuller

102: ¥547.4681Compliant*+50°C9 → 30 V dc-------------------------------------------MCZ/PT100/3CLPTS35Temperature0 → 200 °CCurrentRTD4 → 20 mAFilterDIN Rail----------
8705640000
8705640000

VOLTAGE MONITORING

Weidmuller

101: ¥1,264.3241Lead free / RoHS Compliant*-10 °C...55 °Cfrom the measuring circuitDeclaration of Conformity27-37-18-01LED green = OK / LED yellow/red = alarm status0.5 mm²112.4 mm17.5 mm96.5 mm132 gScrew connection4.425 inch0.689 inch3.799 inchinstruction sheet.pdfWAS5 VMR 1ph4032248377084Markers – refer to Accessories.Limit-value monitoring component  for 1-phase AC / DC voltages with relay output and electrical isolationlimit-value monitoring component in 17.5 mm width for recording AC / DC voltages 24...70 V / 70...140 V / 140...210 V / 210...260 V. A relay contact (CO) with a switching capacity of 750 VA is available on the output side. Input ranges, high/low trip switching behaviour, hysteresis and memory behaviour can be configured using DIP switches. Switching threshold can be adjusted using the front-side potentiometer. The input circuit is used for the power supply. The memory function can be activated using an external reset input 18...30 VDC. The input/output/reset have 4 kV of electrical isolation.WAVESERIES, Voltage monitoring, Screw connection2DIN EN 50178EN 55011, EN 61000-6, EN 6132630-21-18-01< 0.3 % of set range3-way isolator24...70 V AC, small = 5 V / large = 10 V, 70–260 VAC, small = 8 V ⁄ large = 16< 300 msDIP switches: ON = 1,2,5,8 / OFF = 3,4,6,73 Ainput/output, input/reset input, reset input/output: 300 V2 kVeff18 V DC250 VInput/output, input/reset input, reset input/output: 4 kVTS 35EC002046Single-phase monitoringDIP switch, Potentiometer, Alarm status reset via reset input or buttonIII≥ 3 mmEC001438587 Years≤ 250 ppm/K---------1260 V AC / DC8 A-------
8705630000
8705630000

VOLTAGE MONITORING

Weidmuller

101: ¥1,709.9961Lead free / RoHS Compliant*0 °C...50 °Cfrom the measuring circuitDeclaration of Conformity27-37-18-01Green LED0.5 mm²112.4 mm22.5 mm96.5 mm120.6 gScrew connection4.425 inch0.886 inch3.799 inchinstruction sheet.pdfWAS2 VMR 3ph4032248377060Markers – refer to Accessories.Limit-value monitoring component   for 1- /3- phase AC and DC voltageswith relay output and electrical isolationlimit-value monitoring component in 22.5 mm width for recording 1-phaseAC/DC voltages 200...400 V or 3-phase AC- voltages of 80...250 V.A relay contact (CO) with a switching capacity of 750 VAis available on the output side.Input ranges, high/low trip alarm, monitored voltage window andswitching behaviour (for working and quiescent currents) can be configured using DIP switchesSwitching threshold can be adjusted with front-side potentiometerPower is supplied via the measured circuit. The I/O circuits have 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 96.5/ 17.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         3 phases 80 V...250 V AC                                      1 phase 200...400 V AC/DC                                      switchableVoltage of measuring circuit max 400 VOutput                                             Relay / COSwitching current 3 ASwitching voltage 6... 250 V AC / 6...60 V DCSwitching threshold via potentiometerVoltage window        small 10 % AC / 20 % DC // large 12 % AC / 25 % DC adjustableHysteresis 5 % AC / 6 % DC of inputTemperature coefficient   < 300 ppm KStep response time        < 300 msAmbient temperature range 0 °C...+50 °C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage               4 kVeff / 1 min. Input / OutputRated voltage                                          600 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType                                                             WA5 VMR 3phWAVESERIES, Voltage monitoring, 5, 250 V, Screw connection2DIN EN 50178EN 55011, EN 61000-6, EN 6132630-21-18-01< 0.3 % of set range3-way isolator5% of final value< 300 msDIP switches: ON = 1,2,4 / OFF = 33 A600 V4 kVeff / 1 min.250 V AC250 V6 kVTS 35EC0020461-/3-phase monitoringDIP switch, Potentiometer, Alarm status reset via reset input or buttonIIIOutput circuit: 1.8 mm; input circuit, output circuit 1/output circuit 2: 3 mm; input/output: 5.5 mmEC001438493 Years≤ 300 ppm/K5------------------
8975590000
8975590000

CURRENT MONITORING

Weidmuller

101: ¥1,256.641Lead free / RoHS Compliant*0 °C...50 °C-Declaration of Conformity50...60 HzLED ON: OK; FLASHING: signal out of range;LED OFF: Error0.5 mm²112.4 mm22.5 mm72 mm101 gScrew connection4.425 inch0.886 inch2.835 inchinstruction sheet.pdfWAS1 CMA LP 1/5/10A EX4050118023640Cross-connectors for power supplies and markers – refer to AccessoriesMonitoring component for AC currents up to 10A with 4...20 mAloop feed and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 HzAC currents 0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.Power is fed to the component via the 4...20 mA current loop on the output side.The input and output circuits have 6 kV of electrical isolation.Approved for ATEX Zone2 and UL C1 D2 applications.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0...1 A / 0...5 A / 0...10 A AC switchable                                      50 / 60 HzVoltage of measuring circuit 250 V ACOutput                                             4...20 mA current loopLoad resistance            < 600 Ohm Strom>1 kOhm / voltageTransmission error               < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power                                     via output-side current loopAmbient temperature range 0 °C...+50 °C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage                               4 kV input against outputRated voltage                                         300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, cULusEX C1D2, ATEX Zone 2Type                                                            WAS1 CMA LP 1/5/10A EXWAVESERIES, Current monitoring, 0...1 A AC/ 0...5 A AC/ 0...10 A AC, 1, 1, Screw connection27-21-01-07-----------------------1-----------DEMKO07ATEX143595Xmax. 100 µA≤ 600 ΩApprox. 24 mA4...20 mA (current loop)10...1 A AC/ 0...5 A AC/ 0...10 A AC
Page 1 / 1