- Home
- Manufacturer
- Weidmüller Holding AG & Co. KG
Board Mount Current Sensors

Weidmüller Holding AG & Co. KG- Board Mount Current Sensors
03
Board Mount Current Sensors - 型号列表
4 parts in total| Mfr Part # | Quantity Available | Price | Standard Package | RoHS | Series | Voltage - Supply | Operating Temperature | Standards | IEC 61000-4-2 | Standard Number | Declaration of Conformity | Accuracy | Frequency | Indicator | Isolation | Hysteresis | Range deg/s | Response Time | Settling Time | Current - Test | Voltage Rating | Voltage - Breakdown | Voltage - Input (Min) | Voltage - Switching AC | Impulse Discharge Current (8/20us) | Depth | Width | Length | Weight | Connector Type | Depth (Inches) | Mounting Rails | Width (Inches) | Length (Inches) | Package Quantity | Type | ETIM 6*0 | Function | GTIN (EAN) | Description | Configuration | Specifications | Firmware Version | Other Specifications | Distance | ET (Volt-Time) | Operational Life | Ingress Protection | Temperature Coefficient | Other Names | Input Type | Input Range | Output Type | Sensor Type | Output Range | Signal Conditioning | Mounting Type | Standard Pack | Voltage - Max | Current - Switching | Number of Inputs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 5000 | 1: ¥2,590.936 | 1 | Lead free / RoHS Compliant | * | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
8473010000 MCZ PT100/3 CLP 0...200C TS 35 -EA CONDITIONER SIGNAL ANALOG 4-20MA Temp transducer for Pt100,0 to 200 deg C weidmuller | 10 | 2: ¥547.468 | 1 | Compliant | * | 9 → 30 V dc | +50°C | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | MCZ/PT100/3CLPTS35 | Temperature | 0 → 200 °C | Current | RTD | 4 → 20 mA | Filter | DIN Rail | - | - | - | - |
| 10 | 1: ¥1,264.324 | 1 | Lead free / RoHS Compliant | * | from the measuring circuit | -10 °C...55 °C | DIN EN 50178 | EN 55011, EN 61000-6, EN 61326 | 30-21-18-01 | Declaration of Conformity | < 0.3 % of set range | 27-37-18-01 | LED green = OK / LED yellow/red = alarm status | 3-way isolator | 24...70 V AC, small = 5 V / large = 10 V, 70–260 VAC, small = 8 V ⁄ large = 16 | 0.5 mm² | < 300 ms | DIP switches: ON = 1,2,5,8 / OFF = 3,4,6,7 | 3 A | input/output, input/reset input, reset input/output: 300 V | 2 kVeff | 18 V DC | 250 V | Input/output, input/reset input, reset input/output: 4 kV | 112.4 mm | 17.5 mm | 96.5 mm | 132 g | Screw connection | 4.425 inch | TS 35 | 0.689 inch | 3.799 inch | instruction sheet.pdf | WAS5 VMR 1ph | EC002046 | Single-phase monitoring | 4032248377084 | Markers – refer to Accessories. | DIP switch, Potentiometer, Alarm status reset via reset input or button | Limit-value monitoring component for 1-phase AC / DC voltages with relay output and electrical isolationlimit-value monitoring component in 17.5 mm width for recording AC / DC voltages 24...70 V / 70...140 V / 140...210 V / 210...260 V. A relay contact (CO) with a switching capacity of 750 VA is available on the output side. Input ranges, high/low trip switching behaviour, hysteresis and memory behaviour can be configured using DIP switches. Switching threshold can be adjusted using the front-side potentiometer. The input circuit is used for the power supply. The memory function can be activated using an external reset input 18...30 VDC. The input/output/reset have 4 kV of electrical isolation. | WAVESERIES, Voltage monitoring, Screw connection | III | ≥ 3 mm | EC001438 | 587 Years | 2 | ≤ 250 ppm/K | - | - | - | - | - | - | - | - | 1 | 260 V AC / DC | 8 A | - | |
| 10 | 1: ¥1,709.996 | 1 | Lead free / RoHS Compliant | * | from the measuring circuit | 0 °C...50 °C | DIN EN 50178 | EN 55011, EN 61000-6, EN 61326 | 30-21-18-01 | Declaration of Conformity | < 0.3 % of set range | 27-37-18-01 | Green LED | 3-way isolator | 5% of final value | 0.5 mm² | < 300 ms | DIP switches: ON = 1,2,4 / OFF = 3 | 3 A | 600 V | 4 kVeff / 1 min. | 250 V AC | 250 V | 6 kV | 112.4 mm | 22.5 mm | 96.5 mm | 120.6 g | Screw connection | 4.425 inch | TS 35 | 0.886 inch | 3.799 inch | instruction sheet.pdf | WAS2 VMR 3ph | EC002046 | 1-/3-phase monitoring | 4032248377060 | Markers – refer to Accessories. | DIP switch, Potentiometer, Alarm status reset via reset input or button | Limit-value monitoring component for 1- /3- phase AC and DC voltageswith relay output and electrical isolationlimit-value monitoring component in 22.5 mm width for recording 1-phaseAC/DC voltages 200...400 V or 3-phase AC- voltages of 80...250 V.A relay contact (CO) with a switching capacity of 750 VAis available on the output side.Input ranges, high/low trip alarm, monitored voltage window andswitching behaviour (for working and quiescent currents) can be configured using DIP switchesSwitching threshold can be adjusted with front-side potentiometerPower is supplied via the measured circuit. The I/O circuits have 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 96.5/ 17.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 3 phases 80 V...250 V AC 1 phase 200...400 V AC/DC switchableVoltage of measuring circuit max 400 VOutput Relay / COSwitching current 3 ASwitching voltage 6... 250 V AC / 6...60 V DCSwitching threshold via potentiometerVoltage window small 10 % AC / 20 % DC // large 12 % AC / 25 % DC adjustableHysteresis 5 % AC / 6 % DC of inputTemperature coefficient < 300 ppm KStep response time < 300 msAmbient temperature range 0 °C...+50 °C Secure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kVeff / 1 min. Input / OutputRated voltage 600 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType WA5 VMR 3ph | WAVESERIES, Voltage monitoring, 5, 250 V, Screw connection | III | Output circuit: 1.8 mm; input circuit, output circuit 1/output circuit 2: 3 mm; input/output: 5.5 mm | EC001438 | 493 Years | 2 | ≤ 300 ppm/K | - | - | - | - | - | - | - | - | - | - | - | 5 |
Page 1 / 1
1