- Home
- Product Categories
cigen-8846A
8846A Series
Fluke 6.5 - digit precision digital multimeters
The Fluke 8846A is a high-precision digital multimeter known for its 6.5-digit resolution, making it a staple in both laboratory and industrial settings. If you're working on projects that require extremely accurate voltage, current, and resistance measurements, this meter is an excellent choice. Its precision is particularly valuable in calibration labs, R&D departments, and quality assurance testing where even small deviations can have significant impacts.
One thing worth noting is the 8846A’s ability to handle a wide range of inputs, from microvolt-level voltage measurements to several hundred amps of current. This versatility makes it a go-to tool for engineers who need to troubleshoot complex systems or perform detailed analysis. Additionally, its robust design and durability ensure it can withstand the rigors of field use, which is crucial in environments where equipment needs to be reliable under harsh conditions.
Another practical benefit is the meter's user-friendly interface, which includes a large, easy-to-read display and intuitive navigation controls. This makes it easier for technicians and engineers to quickly take accurate measurements without needing extensive training. Overall, the Fluke 8846A stands out for its combination of precision, reliability, and usability, making it a trusted tool in many professional environments.
Series Images (3)
Documents & Media
Frequently Asked Questions
8846A - Part List
10 parts in total| Mfr Part # | Quantity Available | Price | Category | Ranging | Type | Weight | Digits or Characters | RoHS | Display Type | Capacitance Range | Function | Other Specifications | Product | Part # Aliases | Product Category | Accuracy | Frequency | Voltage Range | Resistance - Initial (Ri) (Min) | Standard Package | Response | Style | Features | Includes | Display Count | Display Digits | Functions, Extra | SVHC | Tariff No | Response Time | Resistance Tolerance | Voltage - Input (Min) | Voltage - Supply (Min) | Available Frequency Range | Plug Type | Operating Range | Safety Category | Safety Outputs and Type | Data Rate | Resolution | Current - Max | Frequency - Max | Maximum AC Volts | Resolution (Bits) | Capacitance @ Vr, F | Current Rating (Max) | Current Regulation - Load | Accuracy - Highest (Lowest) | Capacitance Ratio Condition | Accuracy - Voltmeter; Ammeter | Voltage - Rated AC (Phase to Phase) | Voltage - Protection Level (VP) (2416) | Width | Height | Length | Size / Dimension | Part Number | Operating Temperature | Temperature Coefficient | Maximum Temperature Limit | Factory Pack Quantity | Current - Modulation | Current - DC Forward (If) (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8846A Digital Multimeters 6.5 DIGIT MULTIMETER 25PPM USBMEM 120V 6.5DigitprecisionMultimter,24ppmUSBmem Fluke 台式 数字万用表, 10A ac 1000V ac, 10 Ω → 1 GΩ, 1 nF → 100 mF, -200 → +600 °C温度测量 Fluke | 10 | 1: ¥10,506.00 | - | Auto | Bench | 8 lbs | 6.5 | RoHS Compliant By Exemption | LCD - 点阵 | 1 nF to 100 mF | 交流电流、交流电压、电容值、通断、直流电流、直流电压、二极管、频率、电阻值、温度 | 1GΩ | Multimeters | 2454021 | Digital Multimeters | 0.0024, 0.06 | 3 Hz to 300 kHz | 100 mVDC to 1000 VDC | 10 Ohms to 1 GOhms | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | CAT I, CAT II | CAT I 1000 V, CAT II 600 V | No | 0.001°C | 10A 直流 | 300kHz | 10A 交流 | 10µΩ | 100mF | ±0.35% + 0.7 | ±0.15% + 0.008 | ±2% + 0.01 | 1pF | Yes | 1000V 交流 | 600 V, 1000 V | 217mm | 88mm | 297mm | 297 x 217 x 88mm | 8846A | +55°C | ±0.22 % | +600°C | - | - | - |
8846A/SU 120V Digital Multimeters Precision Multimeter 6.5 24ppm SW/Cable PREC MLTMTR 6.5DIGI USB W/SFTWRE Fluke | 10 | 1: ¥11,968.068 | - | Auto | Digital (DMM) | 8 lbs | 6.5 Digits | RoHS Compliant By Exemption | VFD, Dual | - | Voltage, Current, Resistance, Capacitance, Temperature, Frequency | - | Multimeters | 2675344 | Digital Multimeters | 0.0024, 0.06 | 3 Hz to 1 MHz | 100 mV to 1 kV | 10 Ohms to 1 GOhms | 1 | Average | Bench | Min/Max/Ave, Data Logging (Internal Memory, RS-232) | Power Cord, Manual, Software, Test Leads | 1000000 | 6.5 | Continuity, dB, Diode Test | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 | - | - |
| 5000 | 1: ¥10,506.00 | - | Auto | Digital (DMM) | - | - | Not applicable / Not applicable | VFD, Dual | - | Voltage, Current, Resistance, Capacitance, Temperature, Frequency | - | - | - | - | - | - | - | - | 1 | Average | Bench | Min/Max/Ave, Data Logging (Internal Memory, RS-232) | Power Cord, Manual, Test Leads | 1000000 | 6.5 | Continuity, dB, Diode Test | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
| 10 | 1: ¥15,650.3088 | - | :Auto | :Bench | 4.75 | :6.5 | - | - | :1nF to 100mF | - | :100mV to 1kV | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | :No SVHC (20-Jun-2013) | 90303100 | :True RMS | :10ohm to 1Gohm | :100µA to 10A | :100mV to 1kV | :3Hz to 1MHz | :Euro | :-200°C to +600°C | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
| 10 | 1: ¥15,650.3088 | - | :Auto | :Bench | 4.75 | :6.5 | - | - | :1nF to 100mF | - | :100mV to 1kV | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | :No SVHC (20-Jun-2013) | 90303100 | :True RMS | :10ohm to 1Gohm | :100µA to 10A | :100mV to 1kV | :3Hz to 1MHz | :UK | :-200°C to +600°C | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | :100µA to 10A | :100µA to 10A | |
| 0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
8846A 120V CAL FLUKE CALIBRATION | 0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
8846A 120V CAL D FLUKE CALIBRATION | 0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
8846A 120V CAL DU FLUKE CALIBRATION | 0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |


fluke