点击放大查看
502N1-2C-S-5VDC
| Manufacturer | |
| Description | Signal Relay • Coil Voltage: 5 VDC • Contact Configuration: DPDT (2 Form C) • Current : 2 A • Mounting: PC Board Terminal • Operating Function: Single Side Stable |
对参数有疑问?问 AI 助手
Electrical
| Current | 2 Amps | Delay Time | operate: approx. 0.5ms ; release: approx. 3.5ms |
| Sensitivity | Ultra-Sensitivity Type | Release Time | 3ms Max. |
| Pick Up Voltage | 75% of rated voltage | Voltage - Supply | 5 VDC |
| Contact Resistance | 50 Mohm Max. / standard type & high sensitivity, 100 Mohm Max. / Ultra-sensitivity type | Voltage - Breakdown | AC 1000V 50/60Hz 1 min. |
| Current Rating (Max) | 30 mA | Insulation Resistance | 1000Mohm Min. (DC 500V) |
| Voltage Dropout (Max) | 5% of rated voltage | Power - Average Forward | approx. 0.15W |
| DC Resistance (DCR) (Max) | 166.7 ohm | Voltage - Rated AC (Phase to Phase) | 180% of rated voltage |
Mechanical
| Sealed | Plastic Sealed | Weight | Approx. 6g |
| Mounting Type | PC Board | Contact Material | Ag + Au-clad |
| Number of Contacts | 2 changeover contacts | Contact Length - Post | AC 1000V 50/60Hz 1 min. |
| Contact Layout, Typical | 2C DPDT | ||
Product Info
| Type | Relays | Function | Single Side Stable |
| Card Standard | Signal Relay | Electrical Life | AC 100,000 operations / DC 300,000 operations (frequency 1,800 operations/hr) |
| Assembly Configuration | Bifurcate crossbar | ||
Environmental
| Vibration | 10 to 50Hz, amplitude 1.5 mm | Operate Time | 7ms Max. |
| Mechanical Life | 15,000,000 operations (frequency 36,000 operations/hr) | Operating Range | 10 to 50Hz, amplitude 1.5 mm |
| Shock Resistance | 100G | Operating Temperature | -25 to +70?C (no freezing) ; -25 to +65?C (no freezing) for standard coil |