ONEIC.US
对参数有疑问?问 AI 助手

Business

Standard Package1

Compliance

RoHSConformStandardsIEC 61010-1
IEC Standard27-21-01-20IEC 61000-4-2IEC 61326-1, NE 21
Safety CategoryKEMA10ATEX0183XApproval Agency MarkingIECEXKEM10.0090X
Declaration of ConformityDeclaration of Conformity

Electrical

SensorCurrent sourceAccuracy< 0.1 % of measuring range
Frequency100 HzIsolation2-way isolator
Range deg/s0.5 mm²Load Current≤ 600 Ω, @ max 23mA
Response Time≤ 5 msVoltage Rating300 Veff
Current - Output0...20 mA, 4...20 mAVoltage - SupplyLoop powered, via 4...20 mA input
Number of Outputs2Voltage - Breakdown2.5 kVeff
Current - Input Bias0...20 mA, 4…20mAFrequency - Output 3100 Hz
Voltage - Input (Min)1.25 V + 0.015 Vout @25°CNo Load Power Consumption30 mW per channel

Mechanical

Depth114.3 mmWidth6.1 mm
Height112.5 mmWeight97 g
Wire Gauge2.5 mm²Connector TypeScrew connection
Depth (Inches)4.5 inchMounting RailsTS 35
Width (Inches)0.24 inchHeight (Inches)4.429 inch
Package Quantityinstruction sheet.pdf

Product Info

TypeACT20M-2CI-2CO-ILP-SSeries*
ETIM 6*0EC002653GTIN (EAN)4032248970001
DescriptionDIN mounting rail, see AccessoriesProduct TypeThe ACT20M-CI-CO-ILP-S passive isolator isolates standard analogue current signals. An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. Power is supplied through the input measuring circuit (input loop-powered). The passive isolator ACT20M-2CI-2CO-ILP-S offers the same functionality, but has two galvanically isolated channels.
ConfigurationnoneSpecificationsStandard signal passive isolator2-channel passive isolator in 6.1 mm width input-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0/4...20 mAOutput                                             0/4...20 mALoad resistance             < 600 OhmTransmission error               < 0,1 % v. E. Limit frequency 100 Hz Auxiliary power                                     0/4...20 mA input current loop Power loss approx. 1.3 W Ambient temperature range -25 °C...+70 °CIsolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                         300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-2CI-2CO-ILP-S
Engineering DataEPLANFirmware VersionSignal converter/insulator, dual channel, Input current loop feed, 2-way isolator, Loop powered, via 4...20 mA input
Other Specifications<1.25 VDescriptive Text Technical DataPower supply optionally over the DIN mounting rail CH20M

Environmental

Temperature-25 °C...+70 °COperate Time699 Years
ET (Volt-Time)EC002479Humidity Range40 °C / 93 % rel. humidity, no condensation
Ingress Protection2Operating Temperature-25 °C...70 °C
Temperature Coefficient≤ 0.01 % / °C