ONEIC.US
8513340000

点击放大查看

8513340000

Manufacturer
Description
Current Monitoring 9-Pin CONDITIONER SIGNAL RAIL MNT
Category
对参数有疑问?问 AI 助手

Business

Other NamesWAS2CMR20/40/60AACStandard PackageBulk

Compliance

RoHSLead free / RoHS CompliantStandardsDIN EN 50178
IEC 61000-4-2EN 55011, EN 61000-6Standard Number30-21-18-01
Declaration of ConformityDeclaration of Conformity

Electrical

SensorHall sensor (internal)Frequency50...60 Hz
IndicatorGreen LEDIsolation3-way isolator
Hysteresis5 % or 10 % of threshold valueRange deg/s0.5 mm²
Response Timetyp. 700 msSettling Time0...40 A / 10 % hysteresis / open-circuit principle
Voltage - Max400 V AC, > 400 V AC depends on conductor insulationCurrent - Test3 A
Voltage Rating300 VCurrent - Carry≤ 2 A
Number of Inputs1Switching EnergyAdjustable 10...100% with front potentiometer
Voltage - Supply24 V DC ± 10 %Number of Outputs1
Current - Switching7 AVoltage - Breakdown4 kVeff / 5 s
Current - Input Bias0...20 A AC/ 0...40 A AC/ 0...60 A ACCurrent Rating (Max)Depends on wire cross-section
Ratio - Input:Output20/ 40/ 60 A AC / relayVoltage - Open Circuit400 VAC, > 400 VAC depending on wire insulation
Voltage - Switching AC250 VVoltage - Switching DC6 V
Current - Average Rectified (Io)23 mA (relay not triggered)/ 47 mA (relay triggered)Impulse Discharge Current (8/20us)4 kV

Mechanical

Depth112.4 mmWidth22.5 mm
Length92.4 mmWeight144 g
TerminationScrew connectionCable Diameter8 mm
Connector TypeScrew connectionDepth (Inches)4.425 inch
Mounting RailsTS 35Width (Inches)0.886 inch
Length (Inches)3.638 inchPackage Quantityinstruction sheet.pdf

Product Info

TypeWAS2 CMR 20/40/60A acSeries*
ETIM 6*0EC002048FunctionOpen-circuit/closed-circuit principle
GTIN (EAN)4032248151707DescriptionCross-connector for power supplies and markers – refer to Accessories
Product Type1510390000ConfigurationDIP switch, Potentiometer
SpecificationsLimit-value monitoring component  for AC currents up to 60A with relay output and electrical isolationlimit-value monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...20 A / 0...40 A / 0...60 A.  A relay contact (CO) with a switching capacity of 750 VA is available on the output side. Input range can be selected using DIP switches. Switching threshold adjustable between 10...90 % using the front-side potentiometer. The 24 VDC power is supplied over the input circuit. The input and output have 4 kV of electrical isolation.Firmware VersionWAVESERIES, Current monitoring, 0...20 A AC/ 0...40 A AC/ 0...60 A AC, 1, 1, Screw connection
Other SpecificationsThis article will no longer be available in the future.

Environmental

Distance≥ 3 mmET (Volt-Time)EC001440
Operational Life533 YearsIngress Protection2
Operating Temperature0 to 50 °CTemperature Coefficient≤ 250 ppm/K

Documents & Media

PDF Document