ONEIC.US
Macromatic Industrial Controls Inc.

Macromatic Industrial Controls Inc.- Time Delay Relays

Macromatic Industrial Controls Inc. is a U.S.-based manufacturer of industrial control and monitoring products, with a history spanning over four decades. Founded on May 1, 1975, when Malcolm Smith acquired the electronic product line from Intermatic Company, the company originally operated in Chicago before moving to Wisconsin. Today, it is headquartered in Menomonee Falls, a northwest Milwaukee suburb, operating as an independent Wisconsin corporation. The company’s core business encompasses the design and production of high-quality relays, timers, and monitoring devices for automation and process control. Its extensive product portfolio includes plug-in relays, octal relays, and power relays for various switching applications. Macromatic also offers a comprehensive range of timing products such as multi-function timers, time delay relays, and alternating relays for load balancing. Additionally, it provides monitoring solutions including voltage and current monitors, phase failure relays, and liquid level controls. Serving industries like manufacturing, HVAC, water/wastewater, and material handling, Macromatic is recognized for reliable engineering and rigorous testing. While a niche player, the company has a strong market presence in North America, known for innovation and durable industrial controls. With a dedicated technical support team, Macromatic continues to deliver solutions that enhance automation efficiency and operational reliability.

03

Time Delay Relays - 型号列表

110 parts in total

Voltage - Supply

Manufacturer

Voltage Range

Drive Voltage (Max Rds On, Min Rds On)

Reset

Indicator

Response Time

Mounting Type

Number of Contacts

Voltage - Input (Min)

Voltage

Contact Layout, Typical

Type

Operating Temperature

Delay Time - ON

Standards

Load

Return Loss

Release Time

Contact Form

Function

Card Standard

Temperature

Note

Protection

Display Type

Voltage - UL

Voltage Rating

Current - Output

Voltage - Peak Reverse (Max)

Termination

Mounting Style

Mechanical Life

Mfr Part #Quantity AvailablePriceVoltage - SupplyMounting TypeContact Layout, TypicalTypeCard StandardLoadResetIndicatorResponse TimeNumber of ContactsTemperatureMechanical LifeStandardsVoltage RatingCurrent Rating (Max)Drive Voltage (Max Rds On, Min Rds On)TerminationContact FormMounting StyleFunctionRelay TypeManufacturerCurrent - OutputNumber of PinsProtectionVoltageVoltage RangeDelay Time - ONDisplay TypeRelease TimeOperating TemperatureReturn LossVoltage - Peak Reverse (Max)Voltage - ULNoteVoltage - Input (Min)HysteresisImpedance - Unbalanced/BalancedSettling TimeCurrent - SensingTrip StatusCurrent - Output 1 (Range)
PMDU
2
PMDU

Relay;E-Mech;PhaseMonitor;SPDT,SP-NC;Cur-Rtg10A;Ctrl-V208-480V;PCBMnt;SMT Phase Monitor Relay Type: Reversal, Loss, Unbalance, Voltage Coil Voltage: 208-480 VAC Contact Configuration: 1A + 1B + 1C SPST-NO + SPST-NC + SPDT Mounting: Surface-Mount Contact Current: 10 Amps

Macromatic

931: ¥793.628208-480 VDoes not require a socket. Can either be mounted directly on 35mm DIN track with no additional parts or to a back-panel with two screws.1A + 1B + 1C SPST-NO + SPST-NC + SPDTMonitorsPhase Monitor RelayLess than 3VAAs standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (5 & 6), the unit switches to manual reset mode and remote manual reset is available.See DatasheetSee DatasheetSPDT & SPNC, N.O.: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC, N.C.: 10A Resistive @ 240V AC/30V DC, 1/3HP @ 240 VAC-28° to 65°C (-20° to 150°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,CE240⁄30VAC⁄VDC10A480VSMTSPDT,SP-NCSMDPhaseMonitorElectroMechanicalPMDSeries10 Amp-n/aFixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out.--LED1to300Sec.-28to+65°CUnit trips on loss of any Phase A, B or CUnit trips if rotation (sequence) of the three phases is anything other than A-B-CAdjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out.--2 - 3%Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a 'Disable' setting adjustment that will turn off the Phase Unbalance Protection----
PMPU
2
PMPU

Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V208-480V;Vol-Rtg240/30AC/DC Phase Monitor Relay Type: Reversal, Loss, Unbalance, Voltage Coil Voltage: 208-480 VAC Contact Configuration: 1C SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps

Macromatic

761: ¥601.936208-480 VACUses an Plug-in 8 Pin Octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog).1C SPDTMonitorsPhase Monitor RelayLess than 3VAAs standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (6 & 7), the unit switches to manual reset mode and remote manual reset is available.See DatasheetSee DatasheetSPDT: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 120/240V AC-28 to 65C (-20 to 150F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A480VPlug-InSPDTSocketPhaseMonitorElectroMechanicalPMPSeries10 Amps8n/aFixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out.--LED1to300Sec.-28to+60°CUnit trips on loss of any Phase A, B or C.Unit trips if rotation (sequence) of the three phases is anything other than A-B-CAdjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out.--2 - 3%Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a 'Disable' setting adjustment that will turn off the Phase Unbalance Protection----
PAP480
2
PAP480

Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V480V;Vol-Rtg240AC;SocketMnt Phase Monitor Relay Type: Phase Reversal, Loss, Undervoltage NOMINAL VOLTAGE 60 Hz: 480V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps

Macromatic

411: ¥396.984480 VUses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog).1C SPDTMonitorsPhase Monitor Relay3VAAutomatic upon correction of faultRed LED on when all conditions are normal, and off when a fault condition has occurredOperate: 50ms, Release: 50ms10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)-28° to 65°C (-20° to 150°F)Full Load: 100,000 operationscULus,UL240VAC10A480VPlug-InSPDTSocketPhaseMonitorElectroMechanicalPAPSeries10 Amp810,000 volts for 20 microseconds-360-460V-LED50ms-28to+65°CUnit trips on loss of any Phase A, B or CUnit trips if sequence of the three phases is anything other than A-B-C.Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point--------
VAKP024D
VAKP024D

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V24DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 24V DC Pick-up Voltage Range: 21-27V DC Drop-out Voltage Range: 16-26V DC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds

Macromatic

251: ¥496.53624 VDC8 Pin OctalDPDTOver / Under VoltageVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green when Relay is Off.Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A24VDCPlug-InDPDTSocketVoltageMonitorElectroMechanicalVAKPSeries10 Amps810,000 volts for 20 microsecondsPick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series)16-27 VDCAdjustable 0.5 - 10 Seconds------Adjustable Pick-Up & Drop-Out Settings-------
VAKPU
2
VAKPU

Relay;E-Mech;VoltageMonitor;SPDT;Cur-Rtg10A;Ctrl-V208-240AC;SocketMnt;8Pin Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 208-240VAC Pick-up Voltage Range: 85-115% of Nominal Voltage Setting Drop-out Voltage Range: 80-95% of Pick-Up Setting Time Delay on Drop-Out: Adjustable 0.1 - 10 Seconds

Macromatic

321: ¥669.528208-240 VAC8 Pin OctalSPDTMonitorsVoltage Monitor RelayLess than 3VAAs standard, reset is automatic upon correction of a fault.Red steady when relay is energized; Green steady when relay is off; and Green rapid flash when in powerup mode.Power Up: 2 seconds fixed delay, Operate: 0.1 - 10 seconds adjustable, Release: 0.1 - 10 seconds adjustableSPDT:10A Resistive @ 240V AC/30V DC, 1/2HP @ 120/240V AC-28° to 65°C (-20° to 150°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL240⁄30VAC⁄VDC10A240VACPlug-InSPDTSocketVoltageMonitorElectroMechanicalVAKPUSeries10 Amps8-Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Adjustable from 80-95% of pick-up setting80-95% of Pick-Up SettingAdjustable 0.1 - 10 Seconds------Adjustable Nominal Voltage Setting 208-240VAC-------
VAKP012D
VAKP012D

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 12V DC Pick-up Voltage Range: 10-14V DC Drop-out Voltage Range: 8-13V DC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds

Macromatic

371: ¥496.53612 VDC8 Pin OctalDPDTOver / Under VoltageVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green when Relay is Off.Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A12VDCPlug-InDPDTSocketVoltageMonitorElectroMechanicalVAKPSeries10 Amps810,000 volts for 20 microsecondsPick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series)8-14 VDCAdjustable 0.5 - 10 Seconds------Adjustable Pick-Up & Drop-Out Settings-------
PCP2
2
PCP2

Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V208-480V;Vol-Rtg240AC;8Pin Phase Monitor Relay Type: Phase Reversal Only NOMINAL VOLTAGE 50/60 Hz: 208-480V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps

Macromatic

181: ¥370.056208-480 VUses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog).1C SPDTMonitorsPhase Monitor Relay3VAAutomatic upon correction of faultRed LED on when all conditions are normal, and off when a fault condition has occurredOperate: 50ms, Release: 50ms10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)-28° to 65°C (-20° to 150°F)Full Load: 100,000 operationscULus,UL240VAC10A480VPlug-InSPDTSocketPhaseMonitorElectroMechanicalPCBSeries10 Amp810,000 volts for 20 microseconds---IndicatorLED50ms-20to+60°Cn/aUnit trips if sequence of the three phases is anything other than A-B-C.---------
VWKP120A
2
VWKP120A

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V120AC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Voltage Band Coil Voltage: 120V AC Over Voltage Range: 120-150V AC Under Voltage Range: 90-120V AC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds

Macromatic

101: ¥496.536120 VAC8 Pin OctalDPDTMonitorsVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green, when Relay is OffOperate: 500ms, Release: Fixed 500 ms (VWP Series) Adjustable 0.5 -10 Seconds (VWKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A120VACPlug-InDPDTSocketVoltageMonitorElectroMechanicalVWKPSeries10 Amps810,000 volts for 20 microsecondsOver Voltage: 100-125% of Nominal Voltage, Under Voltage: 75-100% of Nominal Voltage90-120 VACAdjustable 0.5 - 10 Seconds--------------
COKP01A62
2
COKP01A62

Relay;E-Mech;CurrentMonitor;SPDT;Cur-Rtg10A;Ctrl-V120AC;COSeries Current Monitor Relay Type: Overcurrent Coil Voltage: 120 VAC Contact Configuration: SPDT Mounting: 8 Pin Plug-in Current Range Monitored: 0.1 - 1 AMP

Macromatic

101: ¥574.804120 VAC8 Pin Plug-in1C SPDTOvercurrentCurrent Monitor RelayLess than 5VAAutomatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened.Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized.Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A120VACPlug-InSPDTSocketCurrentMonitorElectroMechanicalCOSeries-8-----------0.1 - 1 Amp--Adjustable (From 50-95% of Pick-Up)Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series)--
COKP10A62
2
COKP10A62

Relay;E-Mech;CurrentMonitor;SPDT;Cur-Rtg10A;Ctrl-V120AC;COSeries Current Monitor Relay Type: Overcurrent Coil Voltage: 120 VAC Contact Configuration: SPDT Mounting: 8 Pin Plug-in Current Range Monitored: 1 - 10 Amps

Macromatic

121: ¥696.592120 VAC8 Pin Plug-in1C SPDTOvercurrentCurrent Monitor RelayLess than 5VAAutomatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened.Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized.Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A120VACPlug-InSPDTSocketCurrentMonitorElectroMechanicalCOSeries-8-----------1 - 10 Amp--Adjustable (From 50-95% of Pick-Up)Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series)--
PAP240
2
PAP240

Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V240V;Vol-Rtg240AC;SocketMnt Phase Monitor Relay Type: Phase Reversal, Loss, Undervoltage NOMINAL VOLTAGE 60 Hz: 240V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps

Macromatic

141: ¥430.644240 VUses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog).1C SPDTMonitorsPhase Monitor Relay3VAAutomatic upon correction of faultRed LED on when all conditions are normal, and off when a fault condition has occurredOperate: 50ms, Release: 50ms10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)-28° to 65°C (-20° to 150°F)Full Load: 100,000 operationscULus,UL240VAC10A240VPlug-InSPDTSocketPhaseMonitorElectroMechanicalPAPSeries10 Amp810,000 volts for 20 microseconds-180-230V-LED50ms-28to+65°CUnit trips on loss of any Phase A, B or CUnit trips if sequence of the three phases is anything other than A-B-C.Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point--------
CAH20A2BD
2
CAH20A2BD

RELAY;CRRNTSENSING;2-20AFAULTTRIPCRRNTRNG;120VACINVLTGE;FXDDELAYPWR-UP Current Monitor Relay Type: Overcurrent or Undercurrent Coil Voltage: 110-120 VAC Mounting: Surface Mount Contact Configuration : 1C SPDT Current Range Monitored: 20 Amps

Macromatic

101: ¥682.652110-120 VACSurface Mount1C SPDTOvercurrent or UndercurrentCurrent Monitor Relay----------------------1 Sec-------120VAC----0.5-50 Sec0.2—20A
PMD600
2
PMD600

Relay;E-Mech;PhaseMonitor;SPDT,SP-NC;Cur-Rtg10A;Ctrl-V575V;PCBMnt;SMT Phase Monitor Relay Type: Reversal, Loss, Unbalance, Voltage Coil Voltage: 575 V Contact Configuration: 1A + 1B + 1C SPST-NO + SPST-NC + SPDT Mounting: Surface-Mount Contact Current: 10 Amps

Macromatic

101: ¥917.252575 VDoes not require a socket. Can either be mounted directly on 35mm DIN track with no additional parts or to a back-panel with two screws.1A + 1B + 1C SPST-NO + SPST-NC + SPDTMonitorsPhase Monitor RelayLess than 3VAAs standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (5 & 6), the unit switches to manual reset mode and remote manual reset is available.See DatasheetSee DatasheetSPDT & SPNC, N.O.: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC, N.C.: 10A Resistive @ 240V AC/30V DC, 1/3HP @ 240 VAC-28° to 65°C (-20° to 150°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,CE240⁄30VAC⁄VDC10A575VSMTSPDT,SP-NCSMDPhaseMonitorElectroMechanicalPMDSeries10 Amp-n/aFixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out.-----Unit trips on loss of any Phase A, B or CUnit trips if rotation (sequence) of the three phases is anything other than A-B-CAdjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out.--2 - 3%Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a 'Disable' setting adjustment that will turn off the Phase Unbalance Protection----
VMKP012D
VMKP012D

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 12 VDC Pick-up Voltage Range: 10-14V DC Drop-out Voltage Range: 8-13V DC Time Delay on Drop-Out: Fixed at 500ms

Macromatic

101: ¥457.3012 VDC8 Pin OctalDPDTOver / Under VoltageVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green when Relay is Off.Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A12VDCPlug-InDPDTSocketVoltageMonitorElectroMechanicalVMKPSeries10 Amps810,000 volts for 20 microsecondsPick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series)8-14 VDCFixed at 500msLED500ms-28to+55°C---Adjustable Pick-Up & Drop-Out Settings-------
VWKP012D
VWKP012D

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Voltage Band Coil Voltage: 12V DC Over Voltage Range: 12-15V DC Under Voltage Range: 9-12V DC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds

Macromatic

191: ¥563.17612 VDC8 Pin OctalDPDTMonitorsVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green, when Relay is OffOperate: 500ms, Release: Fixed 500 ms (VWP Series) Adjustable 0.5 -10 Seconds (VWKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A12VDCPlug-InDPDTSocketVoltageMonitorElectroMechanicalVWKPSeries10 Amps810,000 volts for 20 microsecondsOver Voltage: 100-125% of Nominal Voltage, Under Voltage: 75-100% of Nominal Voltage9-12 VDCAdjustable 0.5 - 10 Seconds--------------
PAP208
PAP208

RELAY;208VAC,10ASPDT,PHASEMONITOR Phase Monitor Relay Type: Phase Reversal, Loss, Undervoltage NOMINAL VOLTAGE 60 Hz: 208V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps

Macromatic

101: ¥493.612208 VUses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog).1C SPDTMonitorsPhase Monitor Relay3VAAutomatic upon correction of faultRed LED on when all conditions are normal, and off when a fault condition has occurredOperate: 50ms, Release: 50ms10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)-28° to 65°C (-20° to 150°F)Full Load: 100,000 operations----------10 Amp-10,000 volts for 20 microseconds-156-198V----Unit trips on loss of any Phase A, B or CUnit trips if sequence of the three phases is anything other than A-B-C.Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point--------
VMP024D
2
VMP024D

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V24DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 24 VDC Pick-up Voltage Range: 21-27V DC Drop-out Voltage Range: 20-26V DC Time Delay on Drop-Out: Fixed at 500ms

Macromatic

101: ¥580.58424 VDC8 Pin OctalDPDTOver / Under VoltageVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green when Relay is Off.Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A24VDCPlug-InDPDTSocketVoltageMonitorElectroMechanicalVMPSeries10 Amps810,000 volts for 20 microsecondsPick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series)20-27 VDCFixed at 500msLED500ms-28to+55°C---Adjustable Pick-Up, Fixed Drop-Out Settings-------
CAH20A8BD
2
CAH20A8BD

RELAY;CRRNTSENSING;2-20AFAULTTRIPCRRNTRNG;120VACINVLTGE;FXDDELAYPWR-UP Current Monitor Relay Type: Overcurrent or Undercurrent Coil Voltage: 24 VAC/VDC Mounting: Surface Mount Contact Configuration : 1C SPDT Current Range Monitored: 20 Amps

Macromatic

101: ¥682.65224 VAC/VDCSurface Mount1C SPDTOvercurrent or UndercurrentCurrent Monitor Relay----------------------1 Sec-------20 Amps----0.5-50 Sec-
VMP012D
2
VMP012D

Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 12 VDC Pick-up Voltage Range: 10-14V DC Drop-out Voltage Range: 9-13V DC Time Delay on Drop-Out: Fixed at 500ms

Macromatic

141: ¥588.94812 VDC8 Pin OctalDPDTOver / Under VoltageVoltage Monitor RelayLess than 3VAAutomatic. Contact Macromatic for information on how to order a unit with Manual Reset.Red Steady when Relay is energized; Green when Relay is Off.Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A12VDCPlug-InDPDTSocketVoltageMonitorElectroMechanicalVMPSeries10 Amps810,000 volts for 20 microsecondsPick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series)9-14 VDCFixed at 500msLED500ms-28to+55°C---Adjustable Pick-Up, Fixed Drop-Out Settings-------
COKP05A62
COKP05A62

Relay;E-Mech;CurrentMonitor;SPDT;Cur-Rtg10A;Ctrl-V120AC;COSeries Current Monitor Relay Type: Overcurrent Coil Voltage: 120 VAC Contact Configuration: SPDT Mounting: 8 Pin Plug-in Current Range Monitored: 0.5 - 5 Amps

Macromatic

181: ¥593.164120 VAC8 Pin Plug-in1C SPDTOvercurrentCurrent Monitor RelayLess than 5VAAutomatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened.Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized.Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.)-28° to 55°C (-20° to 131°F)Mechanical: 10,000,000 operations, Full Load: 100,000 operationscULus,UL,CE240⁄30VAC⁄VDC10A120VACPlug-InSPDTSocketCurrentMonitorElectroMechanicalCOSeries-8-----------0.5 - 5 Amp--Adjustable (From 50-95% of Pick-Up)Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series)--
Page 1 / 6
1