- Home
- Manufacturer
- Macromatic Industrial Controls Inc.
Time Delay Relays

Macromatic Industrial Controls Inc.- Time Delay Relays
Time Delay Relays - 型号列表
110 parts in total| Mfr Part # | Quantity Available | Price | Voltage - Supply | Mounting Type | Contact Layout, Typical | Type | Card Standard | Load | Reset | Indicator | Response Time | Number of Contacts | Temperature | Mechanical Life | Standards | Voltage Rating | Current Rating (Max) | Drive Voltage (Max Rds On, Min Rds On) | Termination | Contact Form | Mounting Style | Function | Relay Type | Manufacturer | Current - Output | Number of Pins | Protection | Voltage | Voltage Range | Delay Time - ON | Display Type | Release Time | Operating Temperature | Return Loss | Voltage - Peak Reverse (Max) | Voltage - UL | Note | Voltage - Input (Min) | Hysteresis | Impedance - Unbalanced/Balanced | Settling Time | Current - Sensing | Trip Status | Current - Output 1 (Range) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PMDU Relay;E-Mech;PhaseMonitor;SPDT,SP-NC;Cur-Rtg10A;Ctrl-V208-480V;PCBMnt;SMT Phase Monitor Relay Type: Reversal, Loss, Unbalance, Voltage Coil Voltage: 208-480 VAC Contact Configuration: 1A + 1B + 1C SPST-NO + SPST-NC + SPDT Mounting: Surface-Mount Contact Current: 10 Amps Macromatic | 93 | 1: ¥793.628 | 208-480 V | Does not require a socket. Can either be mounted directly on 35mm DIN track with no additional parts or to a back-panel with two screws. | 1A + 1B + 1C SPST-NO + SPST-NC + SPDT | Monitors | Phase Monitor Relay | Less than 3VA | As standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (5 & 6), the unit switches to manual reset mode and remote manual reset is available. | See Datasheet | See Datasheet | SPDT & SPNC, N.O.: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC, N.C.: 10A Resistive @ 240V AC/30V DC, 1/3HP @ 240 VAC | -28° to 65°C (-20° to 150°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,CE | 240⁄30VAC⁄VDC | 10A | 480V | SMT | SPDT,SP-NC | SMD | PhaseMonitor | ElectroMechanical | PMDSeries | 10 Amp | - | n/a | Fixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out. | - | - | LED | 1to300Sec. | -28to+65°C | Unit trips on loss of any Phase A, B or C | Unit trips if rotation (sequence) of the three phases is anything other than A-B-C | Adjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out. | - | - | 2 - 3% | Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a 'Disable' setting adjustment that will turn off the Phase Unbalance Protection | - | - | - | - |
PMPU Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V208-480V;Vol-Rtg240/30AC/DC Phase Monitor Relay Type: Reversal, Loss, Unbalance, Voltage Coil Voltage: 208-480 VAC Contact Configuration: 1C SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps Macromatic | 76 | 1: ¥601.936 | 208-480 VAC | Uses an Plug-in 8 Pin Octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog). | 1C SPDT | Monitors | Phase Monitor Relay | Less than 3VA | As standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (6 & 7), the unit switches to manual reset mode and remote manual reset is available. | See Datasheet | See Datasheet | SPDT: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 120/240V AC | -28 to 65C (-20 to 150F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 480V | Plug-In | SPDT | Socket | PhaseMonitor | ElectroMechanical | PMPSeries | 10 Amps | 8 | n/a | Fixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out. | - | - | LED | 1to300Sec. | -28to+60°C | Unit trips on loss of any Phase A, B or C. | Unit trips if rotation (sequence) of the three phases is anything other than A-B-C | Adjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out. | - | - | 2 - 3% | Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a 'Disable' setting adjustment that will turn off the Phase Unbalance Protection | - | - | - | - |
PAP480 Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V480V;Vol-Rtg240AC;SocketMnt Phase Monitor Relay Type: Phase Reversal, Loss, Undervoltage NOMINAL VOLTAGE 60 Hz: 480V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps Macromatic | 41 | 1: ¥396.984 | 480 V | Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog). | 1C SPDT | Monitors | Phase Monitor Relay | 3VA | Automatic upon correction of fault | Red LED on when all conditions are normal, and off when a fault condition has occurred | Operate: 50ms, Release: 50ms | 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) | -28° to 65°C (-20° to 150°F) | Full Load: 100,000 operations | cULus,UL | 240VAC | 10A | 480V | Plug-In | SPDT | Socket | PhaseMonitor | ElectroMechanical | PAPSeries | 10 Amp | 8 | 10,000 volts for 20 microseconds | - | 360-460V | - | LED | 50ms | -28to+65°C | Unit trips on loss of any Phase A, B or C | Unit trips if sequence of the three phases is anything other than A-B-C. | Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point | - | - | - | - | - | - | - | - |
VAKP024D Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V24DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 24V DC Pick-up Voltage Range: 21-27V DC Drop-out Voltage Range: 16-26V DC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds Macromatic | 25 | 1: ¥496.536 | 24 VDC | 8 Pin Octal | DPDT | Over / Under Voltage | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green when Relay is Off. | Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 24VDC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VAKPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series) | 16-27 VDC | Adjustable 0.5 - 10 Seconds | - | - | - | - | - | - | Adjustable Pick-Up & Drop-Out Settings | - | - | - | - | - | - | - |
VAKPU Relay;E-Mech;VoltageMonitor;SPDT;Cur-Rtg10A;Ctrl-V208-240AC;SocketMnt;8Pin Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 208-240VAC Pick-up Voltage Range: 85-115% of Nominal Voltage Setting Drop-out Voltage Range: 80-95% of Pick-Up Setting Time Delay on Drop-Out: Adjustable 0.1 - 10 Seconds Macromatic | 32 | 1: ¥669.528 | 208-240 VAC | 8 Pin Octal | SPDT | Monitors | Voltage Monitor Relay | Less than 3VA | As standard, reset is automatic upon correction of a fault. | Red steady when relay is energized; Green steady when relay is off; and Green rapid flash when in powerup mode. | Power Up: 2 seconds fixed delay, Operate: 0.1 - 10 seconds adjustable, Release: 0.1 - 10 seconds adjustable | SPDT:10A Resistive @ 240V AC/30V DC, 1/2HP @ 120/240V AC | -28° to 65°C (-20° to 150°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL | 240⁄30VAC⁄VDC | 10A | 240VAC | Plug-In | SPDT | Socket | VoltageMonitor | ElectroMechanical | VAKPUSeries | 10 Amps | 8 | - | Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Adjustable from 80-95% of pick-up setting | 80-95% of Pick-Up Setting | Adjustable 0.1 - 10 Seconds | - | - | - | - | - | - | Adjustable Nominal Voltage Setting 208-240VAC | - | - | - | - | - | - | - |
VAKP012D Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 12V DC Pick-up Voltage Range: 10-14V DC Drop-out Voltage Range: 8-13V DC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds Macromatic | 37 | 1: ¥496.536 | 12 VDC | 8 Pin Octal | DPDT | Over / Under Voltage | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green when Relay is Off. | Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 12VDC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VAKPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series) | 8-14 VDC | Adjustable 0.5 - 10 Seconds | - | - | - | - | - | - | Adjustable Pick-Up & Drop-Out Settings | - | - | - | - | - | - | - |
PCP2 Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V208-480V;Vol-Rtg240AC;8Pin Phase Monitor Relay Type: Phase Reversal Only NOMINAL VOLTAGE 50/60 Hz: 208-480V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps Macromatic | 18 | 1: ¥370.056 | 208-480 V | Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog). | 1C SPDT | Monitors | Phase Monitor Relay | 3VA | Automatic upon correction of fault | Red LED on when all conditions are normal, and off when a fault condition has occurred | Operate: 50ms, Release: 50ms | 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) | -28° to 65°C (-20° to 150°F) | Full Load: 100,000 operations | cULus,UL | 240VAC | 10A | 480V | Plug-In | SPDT | Socket | PhaseMonitor | ElectroMechanical | PCBSeries | 10 Amp | 8 | 10,000 volts for 20 microseconds | - | - | - | IndicatorLED | 50ms | -20to+60°C | n/a | Unit trips if sequence of the three phases is anything other than A-B-C. | - | - | - | - | - | - | - | - | - |
VWKP120A Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V120AC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Voltage Band Coil Voltage: 120V AC Over Voltage Range: 120-150V AC Under Voltage Range: 90-120V AC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds Macromatic | 10 | 1: ¥496.536 | 120 VAC | 8 Pin Octal | DPDT | Monitors | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green, when Relay is Off | Operate: 500ms, Release: Fixed 500 ms (VWP Series) Adjustable 0.5 -10 Seconds (VWKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 120VAC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VWKPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Over Voltage: 100-125% of Nominal Voltage, Under Voltage: 75-100% of Nominal Voltage | 90-120 VAC | Adjustable 0.5 - 10 Seconds | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
COKP01A62 Relay;E-Mech;CurrentMonitor;SPDT;Cur-Rtg10A;Ctrl-V120AC;COSeries Current Monitor Relay Type: Overcurrent Coil Voltage: 120 VAC Contact Configuration: SPDT Mounting: 8 Pin Plug-in Current Range Monitored: 0.1 - 1 AMP Macromatic | 10 | 1: ¥574.804 | 120 VAC | 8 Pin Plug-in | 1C SPDT | Overcurrent | Current Monitor Relay | Less than 5VA | Automatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened. | Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized. | Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 120VAC | Plug-In | SPDT | Socket | CurrentMonitor | ElectroMechanical | COSeries | - | 8 | - | - | - | - | - | - | - | - | - | - | - | 0.1 - 1 Amp | - | - | Adjustable (From 50-95% of Pick-Up) | Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series) | - | - |
COKP10A62 Relay;E-Mech;CurrentMonitor;SPDT;Cur-Rtg10A;Ctrl-V120AC;COSeries Current Monitor Relay Type: Overcurrent Coil Voltage: 120 VAC Contact Configuration: SPDT Mounting: 8 Pin Plug-in Current Range Monitored: 1 - 10 Amps Macromatic | 12 | 1: ¥696.592 | 120 VAC | 8 Pin Plug-in | 1C SPDT | Overcurrent | Current Monitor Relay | Less than 5VA | Automatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened. | Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized. | Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 120VAC | Plug-In | SPDT | Socket | CurrentMonitor | ElectroMechanical | COSeries | - | 8 | - | - | - | - | - | - | - | - | - | - | - | 1 - 10 Amp | - | - | Adjustable (From 50-95% of Pick-Up) | Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series) | - | - |
PAP240 Relay;E-Mech;PhaseMonitor;SPDT;Cur-Rtg10A;Ctrl-V240V;Vol-Rtg240AC;SocketMnt Phase Monitor Relay Type: Phase Reversal, Loss, Undervoltage NOMINAL VOLTAGE 60 Hz: 240V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps Macromatic | 14 | 1: ¥430.644 | 240 V | Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog). | 1C SPDT | Monitors | Phase Monitor Relay | 3VA | Automatic upon correction of fault | Red LED on when all conditions are normal, and off when a fault condition has occurred | Operate: 50ms, Release: 50ms | 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) | -28° to 65°C (-20° to 150°F) | Full Load: 100,000 operations | cULus,UL | 240VAC | 10A | 240V | Plug-In | SPDT | Socket | PhaseMonitor | ElectroMechanical | PAPSeries | 10 Amp | 8 | 10,000 volts for 20 microseconds | - | 180-230V | - | LED | 50ms | -28to+65°C | Unit trips on loss of any Phase A, B or C | Unit trips if sequence of the three phases is anything other than A-B-C. | Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point | - | - | - | - | - | - | - | - |
CAH20A2BD RELAY;CRRNTSENSING;2-20AFAULTTRIPCRRNTRNG;120VACINVLTGE;FXDDELAYPWR-UP Current Monitor Relay Type: Overcurrent or Undercurrent Coil Voltage: 110-120 VAC Mounting: Surface Mount Contact Configuration : 1C SPDT Current Range Monitored: 20 Amps Macromatic | 10 | 1: ¥682.652 | 110-120 VAC | Surface Mount | 1C SPDT | Overcurrent or Undercurrent | Current Monitor Relay | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 Sec | - | - | - | - | - | - | - | 120VAC | - | - | - | - | 0.5-50 Sec | 0.2—20A |
PMD600 Relay;E-Mech;PhaseMonitor;SPDT,SP-NC;Cur-Rtg10A;Ctrl-V575V;PCBMnt;SMT Phase Monitor Relay Type: Reversal, Loss, Unbalance, Voltage Coil Voltage: 575 V Contact Configuration: 1A + 1B + 1C SPST-NO + SPST-NC + SPDT Mounting: Surface-Mount Contact Current: 10 Amps Macromatic | 10 | 1: ¥917.252 | 575 V | Does not require a socket. Can either be mounted directly on 35mm DIN track with no additional parts or to a back-panel with two screws. | 1A + 1B + 1C SPST-NO + SPST-NC + SPDT | Monitors | Phase Monitor Relay | Less than 3VA | As standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (5 & 6), the unit switches to manual reset mode and remote manual reset is available. | See Datasheet | See Datasheet | SPDT & SPNC, N.O.: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC, N.C.: 10A Resistive @ 240V AC/30V DC, 1/3HP @ 240 VAC | -28° to 65°C (-20° to 150°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,CE | 240⁄30VAC⁄VDC | 10A | 575V | SMT | SPDT,SP-NC | SMD | PhaseMonitor | ElectroMechanical | PMDSeries | 10 Amp | - | n/a | Fixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out. | - | - | - | - | - | Unit trips on loss of any Phase A, B or C | Unit trips if rotation (sequence) of the three phases is anything other than A-B-C | Adjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out. | - | - | 2 - 3% | Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a 'Disable' setting adjustment that will turn off the Phase Unbalance Protection | - | - | - | - |
VMKP012D Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 12 VDC Pick-up Voltage Range: 10-14V DC Drop-out Voltage Range: 8-13V DC Time Delay on Drop-Out: Fixed at 500ms Macromatic | 10 | 1: ¥457.30 | 12 VDC | 8 Pin Octal | DPDT | Over / Under Voltage | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green when Relay is Off. | Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 12VDC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VMKPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series) | 8-14 VDC | Fixed at 500ms | LED | 500ms | -28to+55°C | - | - | - | Adjustable Pick-Up & Drop-Out Settings | - | - | - | - | - | - | - |
VWKP012D Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Voltage Band Coil Voltage: 12V DC Over Voltage Range: 12-15V DC Under Voltage Range: 9-12V DC Time Delay on Drop-Out: Adjustable 0.5 - 10 Seconds Macromatic | 19 | 1: ¥563.176 | 12 VDC | 8 Pin Octal | DPDT | Monitors | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green, when Relay is Off | Operate: 500ms, Release: Fixed 500 ms (VWP Series) Adjustable 0.5 -10 Seconds (VWKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 12VDC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VWKPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Over Voltage: 100-125% of Nominal Voltage, Under Voltage: 75-100% of Nominal Voltage | 9-12 VDC | Adjustable 0.5 - 10 Seconds | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
PAP208 RELAY;208VAC,10ASPDT,PHASEMONITOR Phase Monitor Relay Type: Phase Reversal, Loss, Undervoltage NOMINAL VOLTAGE 60 Hz: 208V Contact Configuration: SPDT Mounting: 8 Pin Plug-in Contact Current: 10 Amps Macromatic | 10 | 1: ¥493.612 | 208 V | Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16 of Catalog). | 1C SPDT | Monitors | Phase Monitor Relay | 3VA | Automatic upon correction of fault | Red LED on when all conditions are normal, and off when a fault condition has occurred | Operate: 50ms, Release: 50ms | 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) | -28° to 65°C (-20° to 150°F) | Full Load: 100,000 operations | - | - | - | - | - | - | - | - | - | - | 10 Amp | - | 10,000 volts for 20 microseconds | - | 156-198V | - | - | - | - | Unit trips on loss of any Phase A, B or C | Unit trips if sequence of the three phases is anything other than A-B-C. | Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point | - | - | - | - | - | - | - | - |
VMP024D Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V24DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 24 VDC Pick-up Voltage Range: 21-27V DC Drop-out Voltage Range: 20-26V DC Time Delay on Drop-Out: Fixed at 500ms Macromatic | 10 | 1: ¥580.584 | 24 VDC | 8 Pin Octal | DPDT | Over / Under Voltage | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green when Relay is Off. | Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 24VDC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VMPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series) | 20-27 VDC | Fixed at 500ms | LED | 500ms | -28to+55°C | - | - | - | Adjustable Pick-Up, Fixed Drop-Out Settings | - | - | - | - | - | - | - |
CAH20A8BD RELAY;CRRNTSENSING;2-20AFAULTTRIPCRRNTRNG;120VACINVLTGE;FXDDELAYPWR-UP Current Monitor Relay Type: Overcurrent or Undercurrent Coil Voltage: 24 VAC/VDC Mounting: Surface Mount Contact Configuration : 1C SPDT Current Range Monitored: 20 Amps Macromatic | 10 | 1: ¥682.652 | 24 VAC/VDC | Surface Mount | 1C SPDT | Overcurrent or Undercurrent | Current Monitor Relay | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1 Sec | - | - | - | - | - | - | - | 20 Amps | - | - | - | - | 0.5-50 Sec | - |
VMP012D Relay;E-Mech;VoltageMonitor;DPDT;Cur-Rtg10A;Ctrl-V12DC;Vol-Rtg240/30AC/DC Voltage Monitor Relay Type: Over/Undervoltage Coil Voltage: 12 VDC Pick-up Voltage Range: 10-14V DC Drop-out Voltage Range: 9-13V DC Time Delay on Drop-Out: Fixed at 500ms Macromatic | 14 | 1: ¥588.948 | 12 VDC | 8 Pin Octal | DPDT | Over / Under Voltage | Voltage Monitor Relay | Less than 3VA | Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. | Red Steady when Relay is energized; Green when Relay is Off. | Operate: 500ms, Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series) | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 12VDC | Plug-In | DPDT | Socket | VoltageMonitor | ElectroMechanical | VMPSeries | 10 Amps | 8 | 10,000 volts for 20 microseconds | Pick-up: Adjustable from 85-115% of nominal voltage, Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series) | 9-14 VDC | Fixed at 500ms | LED | 500ms | -28to+55°C | - | - | - | Adjustable Pick-Up, Fixed Drop-Out Settings | - | - | - | - | - | - | - |
COKP05A62 Relay;E-Mech;CurrentMonitor;SPDT;Cur-Rtg10A;Ctrl-V120AC;COSeries Current Monitor Relay Type: Overcurrent Coil Voltage: 120 VAC Contact Configuration: SPDT Mounting: 8 Pin Plug-in Current Range Monitored: 0.5 - 5 Amps Macromatic | 18 | 1: ¥593.164 | 120 VAC | 8 Pin Plug-in | 1C SPDT | Overcurrent | Current Monitor Relay | Less than 5VA | Automatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened. | Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized. | Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) | -28° to 55°C (-20° to 131°F) | Mechanical: 10,000,000 operations, Full Load: 100,000 operations | cULus,UL,CE | 240⁄30VAC⁄VDC | 10A | 120VAC | Plug-In | SPDT | Socket | CurrentMonitor | ElectroMechanical | COSeries | - | 8 | - | - | - | - | - | - | - | - | - | - | - | 0.5 - 5 Amp | - | - | Adjustable (From 50-95% of Pick-Up) | Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series) | - | - |

