ONEIC.US
Weidmüller Holding AG & Co. KG

Weidmüller Holding AG & Co. KG- Specialty Test Equipment

Weidmüller is a German pioneer in industrial connectivity, founded in 1948 and headquartered in Detmold, Germany. The company specializes in enabling reliable transmission of power, signals, and data in automation and industrial environments. Its core product portfolio includes a comprehensive range of terminal blocks, printed circuit board connectors, and heavy-duty connectors. Weidmüller also offers electronic interface modules, relay modules, and surge protection devices to complete the connectivity chain. Advanced sensor-actuator cabling and industrial Ethernet solutions underscore its move into smart manufacturing. The group provides high-quality hand and power tools, as well as customized enclosures and marking systems, to support installation and maintenance. With over 80 country representations and manufacturing facilities worldwide, Weidmüller serves customers in machinery, process, and building automation. The company holds a leading global market share in terminal block technology and is recognized for setting industry standards in safe and efficient electrical connections. Continuous focus on sustainable innovation drives its development of solutions for future industrial challenges. In 2013, the group employed 4,600 people, a number that has since grown with its expanding global footprint.

03

Specialty Test Equipment - 型号列表

11 parts in total

Type

GTIN (EAN)

Weight

Firmware Version

Frequency

ETIM 6*0

Ingress Protection

Temperature Coefficient

Product Type

Specifications

Width

Height

Length

Width (Inches)

Height (Inches)

ET (Volt-Time)

Accuracy

Current - Output

Voltage - Supply

Voltage - Input (Min)

Current - Input Bias

RoHS

Standard Number

Length (Inches)

Tool Type

For Use With/Related Products

Standards

IEC Standard

IEC 61000-4-2

Connector Type

Descriptive Text Technical Data

Operating Temperature

Load Current

Number of Outputs

Voltage - Breakdown

Current Rating (Max)

No Load Power Consumption

Other Specifications

Mfr Part #Quantity AvailablePriceStandard PackageRoHSFrequencyWeightTypeETIM 6*0GTIN (EAN)Ingress ProtectionSeriesET (Volt-Time)WidthHeightWidth (Inches)Height (Inches)Firmware VersionStandardsIEC StandardIEC 61000-4-2Declaration of ConformityAccuracyRange deg/sCurrent - OutputVoltage - SupplyVoltage - Input (Min)Connector TypeDescriptive Text Technical DataOperating TemperatureTemperature CoefficientStandard NumberLengthSafety CategoryApproval Agency MarkingSensorIsolationLoad CurrentResponse TimeVoltage RatingNumber of OutputsVoltage - BreakdownCurrent - Input BiasFrequency - Output 3No Load Power ConsumptionDepthWire GaugeDepth (Inches)Mounting RailsPackage QuantityDescriptionProduct TypeConfigurationSpecificationsEngineering DataOther SpecificationsTemperatureHumidity RangeTool TypeFor Use With/Related ProductsLength (Inches)Approval AgencyCurrent - ULCurrent Rating (Max)Current - Input Bias (Max)Mounting TypeSize / DimensionTermination StyleFeaturesMaximum Temperature LimitOperate TimeOutputVisible OutputOutput ResolutionAnalog Input:OutputVoltage/Current - Output 1Voltage - Output (Typ) @ DistanceAdjustment RangeManual Override
8808420000
8808420000

IE-CT TOOL TESTER RJ45 -EA CONTINUITY TESTER

weidmuller

101: ¥2,520.3521Lead free / RoHS Compliant27-20-11-09417 gIE-CTEC000305403224850600227-20-11-09-EC00030570 mm36 mm2.756 inch1.417 inchContinuity tester for data cables-------------41-11-36-37140 mm-------------------------Continuity TesterMultiple Cables5.512 inch------------------
7940010908
7940010908

PROCESS MONITORING

Weidmuller

101: ¥4,409.801Lead free / RoHS Compliant------*-------------------------------------------------------------------
7940015988
7940015988

PROCESS MONITORING

Weidmuller

101: ¥4,409.801Lead free / RoHS Compliant------*-------------------------------------------------------------------
1924990000
1924990000

SENSOR COUPLING MODULE

Weidmuller

101: ¥346.1881Lead free / RoHS Compliant27-24-26-9263 gSAI-ASI T FFEC002585403224856610527-27-92-12*EC002585------------------30-21-18-01-----------------------------------------------
1925010000
1925010000

SENSOR COUPLING MODULE

Weidmuller

101: ¥369.3761Lead free / RoHS Compliant27-24-26-9285 gSAI-ASI T FREC002585403224856621127-27-92-12*EC002585------------------30-21-18-01-----------------------------------------------
7940010202
7940010202

CALIBRATION DEVICE

Weidmuller

101: ¥2,417.8761Lead free / RoHS Compliant27-21-09-90348 gP275EC001417403224856580127-21-09-90--62 mm112 mm2.441 inch4.409 inchPM, Calibration deviceDIN EN 5017827-21-92-90DIN EN 61326Declaration of Conformity0.25 % of signal range0.5 mm²0 (4)...20 mABatteries, 2 x 9-V blocks 6...22 mA (current source)2 mA (current sink)0...5 V / 1...5 V; 0...200 mV / 40...200 mVSocketIncluding two one-metre-long test leads sw/rt with banana plug/terminal and one bridge lead0 °C...60 °Ctyp. 40 ppm @ °C30-21-18-0131 mm-------------------------CalibratorSound Levels1.22 inch----------0 or 100 % with toggle switch0...100 % with precision potentiometer0.01 mA< 1 µA4...45 V DC250 Ω @ V / 10 Ω @ mV0 (4)...20 mA / 0...200 mA (current source).0...5 V (voltage source) or as current sinkselectable with toggle switchQuick start guide, english
7940010194
7940010194

CALIBRATION DEVICE

Weidmuller

101: ¥6,624.6281Lead free / RoHS Compliant-----------------------------------------------------CalibratorSound Levels-------------------
1176040000
2
1176040000

Signal Isolator/ Splitter (2-Wire System) Is Supplied Via The Output Current Loop And Has An Analogue DC Current Input SIGNAL CONVERTER/DISCONNECTOR DIN Rail 接口继电器模块, 4 → 20mA

Weidmuller

101: ¥1,268.7441Conform100 Hz80 gACT20M-CI-CO-OLP-SEC00265340322489701552*EC0024796.1 mm112.5 mm0.24 inch4.429 inchSignal converter/insulator, Output current loop powered, 2-way isolator, Output loop poweredIEC 61010-127-21-01-20IEC 61326-1, NE 21Declaration of Conformity< 0.05 % of measuring range0.5 mm²4...20 mAOutput loop poweredTypical 2.5 VScrew connectionPower supply optionally over the DIN mounting rail CH20M-25 °C...70 °C≤±0.02 µA x (Δ °C x V supply) @ Tamb > 25 °C-6.1mmKEMA10ATEX0183XIECEXKEM10.0090XCurrent source2-way isolator≤ 600 Ω (channel 1 +2), @ max 23mA≤ 5 ms300 Veff12.5 kVeff / 1 min.4…20mA100 Hz30 mW per channel114.3 mm2.5 mm²4.5 inchTS 35instruction sheet.pdfDIN mounting rail, see AccessoriesThe passive isolator ACT20M-CI-CO-OLP-S isolates standard analogue current signals. An analogue input current signal is linearly converted into an analogue output current signal and is galvanically isolated. Power is supplied through the output measuring circuit (output loop-powered).noneStandard signal isolating amplifier1-channel signal isolating amplifier in 6.1 mm width output-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0/4...20 mAOutput                                             0/4...20 mALoad resistance             < 600 OhmTransmission error             < 0,1 % v. E. Limit frequency 100 HzAuxiliary power                                     0/4...20 mA output current loopPower loss approx. 0.9 WAmbient temperature range -25 °C...+70 °C Isolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                          300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-CI-CO-OLP-SEPLANTypical 2.5 V-25 °C...+70 °C40 °C / 93 % rel. humidity, no condensation---ATEX-KEMA,cULus,DNV,EAC,FM 认证,IECEx-KEMA,ME25E337701.pdf4 → 20mA4 → 20mADIN Rail6.1 x 114.3 x 112.5mm螺丝切断频率高达 100 Hz,无源隔离器,步进响应时间 ≤5 ms+70°C---------
1176070000
2
1176070000

SIGNAL CONVERTER/DISCONNECTOR DIN Rail 接口继电器模块, 0 → 20 mA, 4 → 20 mA, 16V dc

Weidmuller

101: ¥1,146.6841Conform100 Hz80 gACT20M-CI-CO-ILP-SEC00265340322489701482*EC0024796.1 mm112.5 mm0.24 inch4.429 inchSignal converter/insulator, Input current loop feed, 2-way isolator, Loop powered, via 4...20 mA inputIEC 61010-127-21-01-20IEC 61326-1, NE 21Declaration of Conformity< 0.1 % of measuring range0.5 mm²0...20 mA, 4...20 mALoop powered, via 4...20 mA input1.25 V + 0.015 Vout @25°CScrew connectionPower supply optionally over the DIN mounting rail CH20M-25 °C...70 °C≤ 0.01 % / °C-6.1mmKEMA10ATEX0183XIECEXKEM10.0090XCurrent source2-way isolator≤ 600 Ω (channel 1 +2), @ max 23mA≤ 5 ms300 Veff12.5 kVeff / 1 min.0...20 mA, 4…20mA100 Hz30 mW per channel114.3 mm2.5 mm²4.5 inchTS 35instruction sheet.pdfDIN mounting rail, see AccessoriesThe ACT20M-CI-CO-ILP-S passive isolator isolates standard analogue current signals.An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. Power is supplied through the input measuring circuit (input loop-powered).noneStandard signal passive isolator1-channel passive isolator in 6.1 mm width input-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                          0/4...20 mAOutput                                              0/4...20 mALoad resistance             < 600 OhmTransmission error               < 0,1 % v. E. Limit frequency 100 HzAuxiliary power                                     0/4...20 mA input current loopPower loss approx. 0.9 WAmbient temperature range -25 °C...+70 °C Isolation                                 EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                          300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-CI-CO-ILP-SEPLAN<1.25 V-25 °C...+70 °C40 °C / 93 % rel. humidity, no condensation---ATEX-KEMA,cULus,DNV,EAC,FM 认证,IECEx-KEMA,ME25-0 → 20 mA, 4 → 20 mA4 → 20mADIN Rail6.1 x 114.3 x 112.5mm螺丝切断频率高达 100 Hz,无源隔离器,步进响应时间 ≤5 ms+70°C699 Years--------
1176050000
1176050000

SIGNAL CONVERTER/DISCONNECTOR

Weidmuller

101: ¥1,834.5041Conform100 Hz96 gACT20M-2CI-2CO-OLP-SEC00265340322489699992*EC0024796.1 mm112.5 mm0.24 inch4.429 inchSignal converter/insulator, dual channel, Output current loop powered, 2-way isolator, Output loop poweredIEC 61010-127-21-01-20IEC 61326-1, NE 21Declaration of Conformity< 0.05 % of measuring range0.5 mm²4...20 mAOutput loop poweredTypical 2.5 VScrew connectionPower supply optionally over the DIN mounting rail CH20M-25 °C...70 °C≤± 0.07 µA x (Δ °C x V supply) @ Tamb < 25 °C, ≤±0.02 µA x (Δ °C x V supply) @ Tamb > 25 °C--KEMA10ATEX0183XIECEXKEM10.0090XCurrent source2-way isolator≤ 600 Ω (channel 1 +2), @ max 23mA≤ 5 ms300 Veff22.5 kVeff / 1 min.4...20 mA100 Hz30 mW per channel114.3 mm2.5 mm²4.5 inchTS 35instruction sheet.pdfDIN mounting rail, see AccessoriesThe passive isolator ACT20M-CI-CO-OLP-S isolates standard analogue current signals. An analogue input current signal is linearly converted into an analogue output current signal and galvanically isolated. Power is supplied through the output measurement circuit (output loop-powered). The passive isolator ACT20M-2CI-2CO-OLP-S offers the same functionality, but has two galvanically isolated channels..noneStandard signal isolating amplifier2-channel signal isolating amplifier in 6.1 mm width output-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0/4...20 mAOutput                                             0/4...20 mALoad resistance             < 600 OhmTransmission error             < 0,1 % v. E. Limit frequency 100 HzAuxiliary power                                     0/4...20 mA output current loop Power loss approx. 1.2 W Ambient temperature range -25 °C...+70 °C Isolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                         300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-2CI-2CO-OLP-SEPLANTypical 2.5 V-25 °C...+70 °C40 °C / 93 % rel. humidity, no condensation----E337701.pdf----------------
1176080000
1176080000

SIGNAL CONVERTER/DISCONNECTOR

Weidmuller

101: ¥1,834.5041Conform100 Hz97 gACT20M-2CI-2CO-ILP-SEC00265340322489700012*EC0024796.1 mm112.5 mm0.24 inch4.429 inchSignal converter/insulator, dual channel, Input current loop feed, 2-way isolator, Loop powered, via 4...20 mA inputIEC 61010-127-21-01-20IEC 61326-1, NE 21Declaration of Conformity< 0.1 % of measuring range0.5 mm²0...20 mA, 4...20 mALoop powered, via 4...20 mA input1.25 V + 0.015 Vout @25°CScrew connectionPower supply optionally over the DIN mounting rail CH20M-25 °C...70 °C≤ 0.01 % / °C--KEMA10ATEX0183XIECEXKEM10.0090XCurrent source2-way isolator≤ 600 Ω, @ max 23mA≤ 5 ms300 Veff22.5 kVeff0...20 mA, 4…20mA100 Hz30 mW per channel114.3 mm2.5 mm²4.5 inchTS 35instruction sheet.pdfDIN mounting rail, see AccessoriesThe ACT20M-CI-CO-ILP-S passive isolator isolates standard analogue current signals. An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. Power is supplied through the input measuring circuit (input loop-powered). The passive isolator ACT20M-2CI-2CO-ILP-S offers the same functionality, but has two galvanically isolated channels.noneStandard signal passive isolator2-channel passive isolator in 6.1 mm width input-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0/4...20 mAOutput                                             0/4...20 mALoad resistance             < 600 OhmTransmission error               < 0,1 % v. E. Limit frequency 100 Hz Auxiliary power                                     0/4...20 mA input current loop Power loss approx. 1.3 W Ambient temperature range -25 °C...+70 °CIsolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                         300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-2CI-2CO-ILP-SEPLAN<1.25 V-25 °C...+70 °C40 °C / 93 % rel. humidity, no condensation------------699 Years--------
Page 1 / 1
1